![SEW MOVIAXIS MX Operating Instructions Manual Download Page 158](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008158.webp)
158
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
6
Displays of the supply and axis modules
Operation
6.2
Displays of the supply and axis modules
Operating display of the 7-segment display
Error display of the 7-segment display
The MOVIAXIS
®
MX multi-axis servo drive detects any errors that occur and displays
them as error code. Each error is clearly defined by its error code and corresponding
attributes, such as
• the error response,
• the final status after executing the error response,
• the type of reset response.
Error message
with two 7-seg-
ment displays
The error codes are indicated as flashing numeric values in the axis and supply module.
The error code is displayed in the following display sequence:
In addition to the error code, a "sub-error code" has been defined to further localize the
reason for the error. The "sub-error code" can be read by the operator via the commu-
nication connection.
The display can jump back to the statistical operation display depending on the type of
error and the response programmed for an error.
Error in the supply
module
Errors in the supply module are reported to the axis and processed by the axis.
You execute a reset by interrupting the 24 V electronics supply or via the software.
• The two 7-segment displays indicate the operating status of the supply modules
and axis modules.
• All settings and functions relating to startup of the axis system are located in the
axis module. That is the reason for more operating displays in the axis module than
in the supply module. The supply module is not equipped with any programmable
intelligence.
• Responses to detected errors and warnings take place in the axis module only. The
error and warnings are, however, displayed in the axis module and to some extent
in the supply module. For some events, other numbers may be displayed in the axis
module than in the supply module. These events are marked in the operating dis-
play table of the supply module.
• The displays for the axis modules and the supply modules are therefore described
separately.
53052AXX
Figure 102: Example: Error display of error 07 at the axis module
0.5 s
0.25 s
1.0 s
0.25 s
Summary of Contents for MOVIAXIS MX
Page 2: ...SEW EURODRIVE Driving the world...
Page 210: ......