4
Installation notes
Mechanical installation
Manual – MOVI‑C
®
CONTROLLER standard UHX25A
18
4
Installation notes
4.1
Mechanical installation
CAUTION
Risk of injury to persons and damage to property.
Never install defective or damaged MOVI-C
®
CONTROLLERs.
•
Before installation, check the device for external damage. Replace any damaged
device.
4.1.1
Minimum clearance and mounting position
MOVI‑C
®
CONTROLLER is installed in the control cabinet. Observe the following for
installation:
•
To ensure unobstructed cooling of the MOVI-C
®
CONTROLLER, leave a minimum
clearance of 100 mm above and below the device's housing. Make sure air circula-
tion in the clearance is not impaired by cables or other installation equipment.
•
Ensure
unobstructed
cooling
air
supply
and
make
sure
that
the
MOVI‑C
®
CONTROLLER is not exposed to the warm exhaust air from other
devices.
•
There is no need for clearance at the sides of the device. You may connect the
MOVI‑C
®
CONTROLLER and other devices (e.g. MOVIDRIVE
®
modular) in series.
•
Install the devices only vertically. You must not install them horizontally, tilted or
upside down.
The MOVI-C
®
CONTROLLER is mounted onto a mounting rail.
4.2
Electrical installation
INFORMATION
Installation with protective separation.
The device meets all requirements for protective separation of power and electronics
connections in accordance with EN 61800‑5‑1. The connected signal circuits have to
meet the requirements according to SELV (
S
afe
E
xtremely
L
ow
V
oltage) or PELV
(
P
rotective
E
xtra
L
ow
V
oltage) to ensure protective separation. The installation must
meet the requirements for protective separation.
25800736/EN – 08/2018