Manual – DFE32B Fieldbus Interface PROFINET IO
7
Read/write parameters via data set 47
Parameterization via PROFIdrive Data Set 47
7.3.3
Error codes of the PROFINET services
The following table shows possible error codes of PROFINET services that may occur
in the event of an error in the communication on PROFINET telegram level. This table
is relevant if you want to write your own parameterization module based on the
PROFINET services because the error codes are reported directly back on the telegram
level.
Error_Class (from
PROFINET specification)
Error_Code (from PROFI-
NET specification)
PROFINET Parameter channel
0x0 ... 0x9 hex = reserved
0xA = application
0x0 = read error
0x2 = module failure
0x3 to 0x7 = reserved
0x8 = version conflict
0xA to 0xF = user specific
0xB = access
0x0 = invalid index
0xB0 = No data block Index 47 (DB47);
parameter requests are not supported
0x1 = write length error
0x2 = invalid slot
0x3 = type conflict
0x4 = invalid area
0x5 = state conflict
0xB5 = Access to DB 47 temporarily not pos-
sible due to internal processing status
0x6 = access denied
0x7 = invalid range
0xB7 = WRITE DB 47 with error in the DB 47
header
0x8 = invalid parameter
0x9 = invalid type
0xA to 0xF = user specific
0xC = resource
0x0 = read constraint conflict
0x1 = write constraint conflict
0x2 = resource busy
0x3 = resource unavailable
0x4..0x7 = reserved
0x8..0xF = user specific
0xD...0xF = user specific
Error_Class
7
6
5
4
3
3
2
0
Error_Code
Bit:
0
0
I