Operating Instructions – Synchronous Compact Servomotors CMDV55 – CMDV162
21
5
Connecting the motor and the encoder system via plug connector SM. / SB.
Electrical Installation
The right-angle plug connectors can be rotated to achieve the required position.
Adjustable connectors (examples)
5.5
Connecting the motor and the encoder system via plug connector SM. / SB.
Servomotors are supplied with the SM. / SB. plug connector system.
In the basic version, SEW-EURODRIVE delivers servomotors with a radial connector on
the motor end and without mating connector. Right-angle connectors are available as
option.
The encoder system is connected using a separate 12-pin round plug connector.
The mating connectors can be ordered separately or together with the motor.
All servomotors are equipped with quick-lock right-angle connectors (SpeedTec). If you
use connectors without quick lock, the O-ring serves as vibration protection. The
connector can only be screwed on until it reaches the O-ring. The connector is always
sealed at the bottom.
If you use self-assembled cables with quick lock, you must remove the O-ring.
INFORMATION
•
Comply with the permitted bending radii of the cables.
•
When using low-capacity trailing cables, the bending radii are larger than for the
previously used standard cables.
•
SEW-EURODRIVE recommends the use of low-capacity cables.
INFORMATION
The connector should only be rotated to install and connect the motor.
Do not turn the plug connector regularly once it has been installed.
NOTICE
Potential damage to the right-angle connector.
Possible damage to property.
•
Do not align the right-angle connector frequently.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]