Chapter 2:
Product
description
30
v3.3-a 12/07/2022
Tip
The use of dust covers is recommended for the unused SFP/SFP+ slots.
2.6 Installing the Switch in a Rack
The devices have been designed to be mounted in a standard 19-inch (48.3 cm) equipment rack
and thus respect the physical dimensions previously stated.
Recommendations
The following guidelines are provided to prevent bodily-injury when mounting or
servicing this unit in a rack:
-
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
-
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
-
If the equipment rack is on wheels, ensure that the brakes are engaged and
that the rack is stabilized.
Accessories
The screws needed to properly mount the device to the rack are not shipped with
the equipment, nor the system ground kit. The device already mounts the L-brackets
and is provided with a power cord C13 (European).
Airflow consideration
There are no standards for airflow in rack system, but the device should be
configured accordingly to the emplacement of hot and cold aisles. The default
airflow of the device is from front-panel (cold) to back-panel (hot).
In order to properly mount the device to a rack cabinet follows the given instructions:
🗹
Step 1:
Place the device on the floor or on a sturdy table near the rack.
🗹
Step 2:
Use a tape measure to verify the interior dimensions of the rack.
🗹
Step 3:
Carefully lift the device and position the rear of the device between the equipment
rack mounting posts and slide the device into the rack until the L brackets on the sides of
the device are flush with the equipment rack front posts.