Installation and Service Manual

5

SAFETY

IMPORTANT SAFETY INSTRUCTIONS

Carefully read all safety messages in this manual. Learn how to operate the A&W Tower unit
properly. Do not allow anyone to operate the unit without proper training and keep it in proper
working condition. Unauthorized modifications to the A&W Tower may impair function and/or
safety and affect the life of the unit.

CARBON DIOXIDE WARNING

QUALIFIED SERVICE PERSONNEL

SHIPPING, STORAGE, AND RELOCATION

ADDITIONAL WARNINGS

Installation and start-up of this equipment should be done by a qualified service technician. Operation,
maintenance, and cleaning information in this manual are provided for the user/operator of the equipment.

Save these instructions.

DANGER:

 Carbon Dioxide (CO

2

) displaces oxygen. Exposure to a high concentration of CO

2

 gas

causes tremors, which are followed rapidly by loss of consciousness and suffocation. If a CO

2

 gas leak

is suspected, particularly in a small area, immediately ventilate the area before repairing the leak. CO

2

lines and pumps should not be installed in an enclosed space. An enclosed space can be a cooler or
small room or closet. This may include convenience stores with glass door self serve coolers. If you
suspect CO

2

 may build up in an area, venting of the B-I-B pumps and / or CO

2

 monitors should be utilized.

WARNING: 

Only trained and certified electrical and plumbing technicians should service this unit.

All wiring and plumbing must conform to national and local codes.

CAUTION:

 Before shipping, storing, or relocating this unit, syrup systems must be sanitized. After

sanitizing, all liquids (sanitizing solution and water) must be purged from the unit. A freezing envi-
ronment causes residual sanitizing solution or water remaining inside the unit to freeze, resulting
in damage to internal components.

Summary of Contents for BLADE TOWER

Page 1: ...icy of continuous product development and improvement this information is subject to change at any time without notice April 01 2008 REV0 Notice DO NOT throw this manual away This manual contains impo...

Page 2: ...__________________________________________________ Serial Number _______________________________________________________________________ Installation Date _____________________________________________...

Page 3: ...NIT INSPECTION 6 PRE INSTALLATION CHECK LIST 6 STARTING YOUR BEVERAGE SYSTEM AND DISPENSER 6 SPECIFICATIONS 6 BLADE TOWER DIMENSIONS 7 COUNTER TOP FOOTPRINT 7 UNIT INSTALLATION 8 BASIC B I B SYSTEM PR...

Page 4: ...OW TO DISASSEMBLE TOWER COMPONENTS 14 CLEANING EQUIPMENT AND SUPPLIES 14 CLEANING SANITIZING THE DISPENSING VALVES PRODUCT LINES 14 MAINTENANCE SCHEDULE 15 NIGHTLY SHUTDOWN PROCEDURE 15 CLEANING AND S...

Page 5: ...CO2 gas causes tremors which are followed rapidly by loss of consciousness and suffocation If a CO2 gas leak is suspected particularly in a small area immediately ventilate the area before repairing...

Page 6: ...tank Gas connectors for tank Beverage dispenser Beverage tubing CO2 tank Beverage tanks Stepless Oetiker clamps Chain for CO2 tank Double Check Doyouhaveenoughspacetoinstallthedispenser Is the counter...

Page 7: ...ER TOP AREA CAUTION Cutting the counter top may decrease its strength Counter should be braced to support the dispenser counter top weight plus ice storage ca pacity and weight of icemaker if applicab...

Page 8: ...carbonator tank Do so by lifting the pressure relief valve tab on the carbonator tank until water comes out of the relief valve 7 Check water and beverage lines for leaks if there are no leaks fasten...

Page 9: ...ration below shows the optional flush mount drain setup Part Number 020001388 If using the optional flush mount drain be sure to plumb according to local codes PLUMBING DIAGRAM LOCATION A plumbing dia...

Page 10: ...10 Installation and Service Manual INSTALLATION SINGLE TOWER PLUMBING DUAL TOWER PLUMBING...

Page 11: ...for 5 seconds 4 Record volume in a volume cup or ratio cup 5 Adjust the water flow rate as needed until 10 ounces of water is measured in a 5 second 2 oz sec dis pense Set the syrup flow rate 1 Adjus...

Page 12: ...nternal External Carbonator tank Combines CO2 gas and tap water to form carbonated water The car bonator is the carbonator tank water pump and wa ter pump motor 5 CO2 cylinder Holds highly pressurized...

Page 13: ...t Contact MBE at 1 800 367 4233 for more information about our ProActive Maintenance Program 1 Conduct the daily and nightly recommended mainte nance of the machine 2 Perform the monthly recommended m...

Page 14: ...embly 1 Remove tower housing cover by removing the thumb screw on the side 2 Turn OFF both shut off valves on the flow control base and remove pressure by pulling the dispense handle to the ON positio...

Page 15: ...ild detergent Rinse with potable water Weekly Outside dispenser cabinet Wash with clean water and mild detergent Wipe dry Every 3 months Syrup circuits Sanitize each syrup circuit See Cleaning and San...

Page 16: ...uct line to the pressure tank containing the sanitizing solution or place the bag in box connector in sanitizing solution Remove branch port cover on bag in box connector to allow suction of sanitizin...

Page 17: ...tap water 4 Connect syrup connector to BIB connector and im merse both into Bucket 1 A bag side connector can be created by cutting the connector from an empty disposable syrup bag 5 Draw rinse water...

Page 18: ...or to the proper setting Defective HP regulator Check repair replace HP regulator CO2 line pinched kinked or obstructed Check repair replaceCO2 line One valve will not dispense anything Is there power...

Page 19: ...s Clogged No Power Check Liquid Level Control Board For Clogging For Mechanical For Clogging For Mechanical Syrup Push Pressure Check Valves in Water and Product Lines If soda water check valve is bad...

Page 20: ...N 47172 1868 Tel 812 246 7000 800 367 4233 Fax 812 246 9922 www manitowocbeverage com In accordance with our policy of continuous product development and improvement this information is subject to cha...

Reviews: