background image

This water cooler is certified to

NSF/ANSI 61.

GENERAL

Self-contained, electric refrigerated, bi-level 
wall-mounted water cooler designed to be 
easily accessible to physically challenged 
individuals. When properly installed, unit meets
state and federal requirements 

for both 

children or adults

as defined by the

Americans with Disabilities Act. Barrier walls
required or apron installed to meet cane touch
prerequisite. Unit is certified to NSF/ANSI 61,
and meets requirements of the Safe Drinking
Water Act. Unit provides 50° F water at 80° F
inlet water and 90° F ambient.

CABINET

Stainless steel panels resist wear and corrosion.
Durable satin finish helps hide water spots and
fingerprints.

COOLER TOP

Non-corrosive stainless steel cooler top, no.
300 series with satin finish resists stains and
corrosion and is easy to maintain. Anti-splash
ridge reduces splatter. Contoured to insure
proper drainage.

BUBBLER

Exclusive one-piece, chrome-plated two-stream
mound-building bubbler with non-removable
anti-squirt feature and integral hood insures a
satisfying drink of water.

PUSH BAR ACTUATION MECHANISM

Self-closing, light-touch push bars on front and
sides with raised letters for the visually
impaired. 

AUTOMATIC STREAM HEIGHT REGULATOR

Self-closing assembly is located inside unit to
prevent tampering. Unit resists corrosion and
liming. A constant stream height is automatically
maintained under line pressures that vary from
20 to 105 psi.

INLET STRAINER

Easily cleaned in-line strainer screen traps 
particles of 140 microns or larger before they
enter the waterway.

TEMPERATURE CONTROL

Positive sensing thermostat for controlling 
temperature of storage tank water. Factory set
at 50° F Adjustable ± 5° F.

STORAGE TANK

Stainless steel evaporator/storage tank for long
life. Waterways are certified to NSF/ANSI 61,
far exceeding the requirements of the Safe
Drinking Water Act.

REFRIGERATION SYSTEM

Hermetically sealed, positive start compressor
with lifetime lubrication and built-in overload
protection, efficient capillary sizing, large
capacity dryer-strainer, and self-lubricated fan
cools copper/aluminum condenser. System
uses R134A refrigerant. Protected by Halsey
Taylor’s Limited 5 Year Warranty.

VENTILATION

Insure proper ventilation by maintaining 
6" (152mm) minimum clearance from 
cabinet louvers to wall.

SUGGESTED SPECIFICATIONS

Shall deliver 8.0 GPH of 50° F water at 90° F
ambient and 80° F inlet water. Shall have
stainless steel basin with removable drain
strainer. Bubbler shall be two-stream, mound
building type. Separate valve and automatic
stream regulator shall be mounted within
cabinet. Refrigeration system shall employ high
efficiency, positive start compressor using
R134A, stainless steel tank with totally
encapsulated insulation and be controlled by
positive sensing thermostat. Shall have front
and side push-bar water controls with raised
lettering for the visually impaired. Cooler shall
comply with ANSI 117:1 and ADA for visual
and motion disabilities. The manufacturer shall
certify the unit to meet the requirements of
NSF/ANSI 61, and the Safe Drinking Water Act.
Unit complies with ARI Standard 1010.

NOTE: Continued product improvement 
makes specifications subject to change 
without notice. See Halsey Taylor website 
for most current spec sheet.

Standard Finish Is Stainless Steel

Optional Finish

Platinum Vinyl

Optional Accessories (extra cost)

Glass Filler Kit

Water Filter

Easy-Flex

Bubbler

Cane Touch Apron

HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523

A16 /

8-2007

MODEL: 

HAC8FSBLR-Q ADA

HACFSDBLR-L/R ADA

Barrier-Free Cooler

Bi-Level

halseytaylor.com

HAC-Q BARRIER-FREE SERIES

Model

GPH Capacity

Base

F.L.

Shipping

Rated

No.

Cooled to 50° F*

Rate

Amps

Weight

Watt

Ambient Air Temp

Cap.

lb.

Usage

70°F

80°F

90°F

100°F

HAC8FSBLR-Q ADA

9.7

8.8

8.0

7.2

8.0

4.0

92

370

*

With projector service and tap water at 80° F

UL listed and complies with ARI Standard 1010

Trap and service stop not included

JOB NAME:

ENGINEER/CONTRACTOR NAME:

APPROVAL:

DATE:

Reviews: