Bi-Level
Barrier-Free Cooler

(CONTINUED)

MOUNTING INSTRUCTIONS

Locate and secure wall hangers to wall. 
Note location of waste trap (in left side unit). 
To insure proper engaging of waste line into
trap, centerline of trap must be 4

1/8

" from wall

face. Mount refrigerated unit on right wall
bracket and secure cabinet to wall using holes
in lower back of frame. Mount fountain 
(non-refrigerated) unit on left wall bracket and
against left side of refrigerated unit. Secure
cabinet to wall using holes in lower back 
of frame. Install connecting waste line to 
tailpieces on both units. Insulated water line
furnished to connect fountain to refrigerated
unit. Connect building water supply line to
“water inlet” connection on refrigerated unit.
Complete instructions packed with unit.

Trap and service stop not included.

OPERATING PRESSURES:

Supply water - 105 psi maximum

Minimum 40 psi supply line pressure required
in special circumstances when both sides of
bilevel are in use simultaneously to ensure
adequate stream height. Does not apply to 
non-refrigerated units.

ELECTRICAL 

Furnished with plug-in, 3-wire grounding type
service cord. Standard 120 volt, 60 Hz, single
phase. Install 120-volt receptacle, rated at 
15-amp minimum, to receive 3-wire parallel
blade grounding type male plug.

*

HANGER BRACKET

RIM HEIGHT

ORIFICE HEIGHT

ORIFICE HEIGHT

C

5/16" (8mm) DIA. (10 HOLES)

B

E

E

E

D

A

F

F

FINISHED FLOOR

L

C

L

C

13 7/8"

352mm

7 1/4"

185mm

2 9/16"

65mm

6 1/4"

159mm

11/16"

18mm

4 9/16"

116mm

18 3/4"

476mm

37 1/2"

952mm

6 1/2"

165mm

18 1/16"

459mm

5 3/4"

146mm

5 3/4"

146mm

5 3/4"

146mm

5 3/4"

146mm

1 3/8"

35mm

1 3/8"

35mm

1 3/8"

35mm

1 3/8"

35mm

2 7/16"

63mm

5"

127mm

10"

254mm

20 3/8"

518mm

26 11/16"

678mm

31 11/16"

805mm

3 1/2"

89mm

4 1/2"

114mm

12 5/16"

313mm

27"

686mm

4 1/8"

105mm

18 5/8"

473mm

2 9/16"

65mm

31 7/8"

810mm

33"

838mm

39 1/2"

1003mm

6 3/4"

172mm

8"

203mm

A. RECOMMENDED WATER SUPPLY LOCATION. 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 

1-1/2" (38mm) OUT FROM WALL SHUT OFF BY OTHERS

B. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/ 2" O.D. DRAIN
C. 1-1/ 2" TRAP NOT FURNISHED
D. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E. INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL
F. 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL

FRONT VIEW

SIDE VIEW

*

Adult ADA requirement. 24" (609mm) for Child ADA.

Adjust other measurements accordingly.

HAC8FSBLR-Q ADA, 
HACFSDBLR-L/R ADA