K
–
R3
Module
K
‐
2
R3
Module
Operational
Options.
1.
Additional
Blower
option:
additional
blower,
installed
in
R3
Module,
could
serve
as:
o
Main
Blower
Parallel
Booster
Fan,
to
increase
dehumidifier’s
total
air
flow,
OR
o
Minimum
Exhaust
Fan.
2.
Full
Flow
Pool
Water
Heater
option
allows
for
direct
piping
into
main
pool
circulating
loop
as
well
as
maximum
compressor
heat
rejection
to
pool
water.
3.
Full
AC
with
NO
Outdoor
Condenser
option
combines
the
Full
Flow
Pool
Water
Heater
and
Minimum
Exhaust
Fan
with
Evaporative
Condenser,
installed
in
the
exhaust
airstream.
R3
Module
External
Systems
Connection.
R3
Module
is
integrated
with
the
dehumidifier
‐
most
external
systems
are
connected
to
the
module
with
or
via
the
dehumidifier,
including
electric
power,
control,
ductwork
and
piping
connections
(except
for
pool
water
connections
for
Full
Flow
Pool
Water
Heater
option).
Air
duct
connections
for
return
and
discharge
air
are
brought,
respectively,
to
the
joined
module
and
dehumidifier
return
air
collars
and
discharge
air
damper
(ducted
per
the
module’s
option
–
main
booster
fan
or
exhaust
fan).
o
No
duct
connections
needed
if
the
module’s
only
one
option
is
Full
Flow
Pool
Water
Heater.
Full
Flow
Pool
Water
Heater
connections
are
normally
brought
through
the
module
piping
connection
panel.
Pic.
K.1
shows
front
‐
right
located
piping
connection
panel,
however
its
location
may
vary
(front
‐
center
or
side
‐
right)
depending
on
R3
Module
size
and
other
features.
Refer
to
your
equipment
submittal
and
other
documentation
for
more
details.
o
For
piping
connections
sizes
and
flow
direction
‐
refer
to
R3
Module
and
the
dehumidifier
labels
and
stickers.
Condensate
(drain
line)
is
to
be
connected
underneath
the
module
floor
(see
Pic.K.1).
Normally
the
R3
module
condensate
connection
comes
with
a
P
‐
trap;
if
the
P
‐
trap
is
not
installed
at
the
factory,
one
must
be
installed
on
‐
site.
Refer
to
the
Installation
Manual
for
additional
information.
R3
Module
Layout
and
Components.
R3
Module
basic
layout,
shown
on
Pic.
K.2
(components,
sensors,
systems
connections,
etc.)
is
similar
for
all
sizes
and
models;
however,
there
might
be
some
variances.
Refer
to
your
equipment
submittal
and
other
documents.
Pic.
K.2
and
description
below
covers
all
options.
Each
R3
Module
has
the
requested
options
only
and
may
not
have
all
options
shown
below
–
refer
to
submittal
documentation
for
details.
The
fan
(booster
or
exhaust)
and
full
flow
pool
heater
options
could
be
installed
together
or
separately
(independently
from
each
other),
while
Full
AC
with
NO
Outdoor
Condenser
option
requires
an
exhaust
fan
AND
full
flow
pool
heater
for
proper
operation
of
the
dehumidifier
overall.
CAUTION!
Current
manual
shows
general/default
connections’
location.
For
details
regarding
specific
dehumidifier
and
R3
Module
connections
(actual
location,
piping
sizes
and
position
dimensions,
circuit
type
and
flow
direction
etc.),
refer
to
the
equipment
submittal
documentation
as
well
as
equipment
labels
and
stickers.
Summary of Contents for CLASSIC NE-002
Page 3: ...B Table of Content B 2 This page is left blank...
Page 10: ...C General Information OMM C S SL 01 C 7 February 2020 Pic C 4 B...
Page 17: ...D Layout and Components D 6 This page is left blank...
Page 21: ...E Sequence of Operation E 4 This page is left blank...
Page 25: ...F Interface and Communication F 4 This page is left blank...