Fan
(51)
is
located
directly
downstream
of
return
air
connection
(52).
Module
discharge
air
damper
(53)
should
be
connected
according
to
module
fan
option:
to
supply
air
ductwork,
if
fan
option
is
main
blower
booster,
or
to
exhaust
ductwork/outdoors,
if
fan
option
is
exhaust.
o
Depending
on
airflow
requirement
and
R3
Module
size,
it
could
be
equipped
with
one
or
two
fans,
serving
same
option.
Full
flow
pool
water
heater
(54)
is
in
the
compartment,
separated
from
the
air
flow
side
of
the
module
(under
the
dehumidifier
compressor
compartment).
The
pool
water
manifold
is
equipped
with
required
controls
and
safeties
(55)
‐
pool
water
flow
switch
and
temperature
sensors
(entering
and
leaving).
o
If
the
full
flow
pool
water
heater
is
installed,
there
is
no
regular
pool
water
heater
in
the
dehumidifier
compressor
compartment.
o
Some
R3
Module
models,
depending
on
the
capacity
required,
may
have
two
pool
water
heaters.
If
the
R3
Module
is
equipped
with
NO
Outdoor
Condenser
Full
AC
option,
evaporative
condenser
box
with
coil
(56)
would
be
installed
between
discharge
air
damper
and
air
filters
(57),
located
downstream
of
the
fan.
Condensate
(collected
in
the
dehumidifier
drain
pan
under
the
evaporator
coil)
is
pumped
by
condensate
pump
(58)
through
the
water
filter
into
the
nozzle
manifold
(59)
to
spray
condenser
coil
with
cool
mist.
Dehumidifier
with
R3
Module
‐
Sequence
of
Operation.
In
general,
the
dehumidifier’s
operation
is
the
same
whether
it’s
equipped
with
the
R3
Module
or
not
‐
refer
to
the
Sequence
of
Operation
chapter
for
additional
information.
Main
Blower
Parallel
Booster
Fan
option.
Same
dehumidifier
operation;
booster
fan
is
controlled
and
operates
in
the
same
way
as
the
dehumidifier
main
blower.
Minimum
Exhaust
Fan
option.
Same
dehumidifier
operation;
minimum
exhaust
fan
is
controlled
and
operates
as
external
minimum
exhaust
fan
(see
Ventilation
in
Sequence
of
Operation
chapter).
Full
Flow
Pool
Water
Heater
option.
Same
dehumidifier
operation;
full
flow
pool
water
heat
exchanger
replaces
regular
one,
while
control
and
operation
of
compressor
circuit
and
pool
heating
feature
stay
the
same.
Full
AC
with
NO
Outdoor
Condenser
option.
Same
dehumidifier
operation
except
for
Air
Conditioning
and
Pool
Heating
–
see
Compressor
Circuit
operation
description
below
(applicable
to
all
R3
Module
sizes).
o
Compressor
heat
rejection
to
outdoors
occurs
via
exhaust
airstream,
without
usage
of
outdoor
condenser
or
fluid
cooler.
o
Note,
that
this
option
(Full
AC
with
NO
Outdoor
Condenser)
is
available
only
in
combination
with
Full
Flow
Pool
Water
Heater
and
Minimum
Exhaust
Fan.
Pic.
K.2
Summary of Contents for CLASSIC NE-002
Page 3: ...B Table of Content B 2 This page is left blank...
Page 10: ...C General Information OMM C S SL 01 C 7 February 2020 Pic C 4 B...
Page 17: ...D Layout and Components D 6 This page is left blank...
Page 21: ...E Sequence of Operation E 4 This page is left blank...
Page 25: ...F Interface and Communication F 4 This page is left blank...