Datalogger-2000
The Datalogger-2000 ESP Gauge interface includes a powerful RTU for local data
storage as well as a robust set of I/O for control and monitoring of other sensors. Push-
button control and a 2-line Character LCD is also onboard for local control and
monitoring of any parameters.
Figure 60. Datalogger-2000
Datalogger-2000 Specifications:
• NEMA 4X Enclosure
• Single SPS-3000 gauge interface
• RTU:
• Internal 4-Line Character LCD
display
• 2 GB Internal removable logging
memory
• 8 Analog Outputs
• 16 Analog Inputs
• 9 Relay Outputs
• 16 Digital Inputs
• 4-20mA mA in and out
• Modbus master - RS485, RS-232
• Modbus slave - RS-485, RS-232,
USB
• Baud rate: 1200 to 38400
• 110-220 VAC/12-24VDC
• Configurable via internal key entry or with
Supplied Software
• Operating Temperature: -10ºC to +70ºC