Doc No. 006-0211-00 Rev AD
Page 59 of 62
ESP Gauge and Surface Control Interface Diagram
The following components are used to provide downhole pressure and temperature
data in an ESP installation as shown in Figure 56.
1. ESP Gauge Surface Readout Interface (SPS-1500/SPS-3000/Scout-
3000/Datalogger-2000)
2. Surge Panel Equipment (Surge Suppressor and Fuse Protection #90D2215 or
#90B2175)
3. Surface Choke - 3-phase choke (P/N 99B990)
4. Motor Head Adapter and WYE point connection
5. Downhole Choke and Sensor Module (Gauge)
VSD
Controller
ESP Gauge
Interface
Modbus or Analog communication
15 VDC
Earth Ground
Gauge
Signal
Gauge
Ground
Surge
Panel
Well Head
Ground
Gauge
Signal
Y-point
Surface
Choke
Motor and Pump
Choke and Sensor
Line Service
Transformer
Power Source
3-Phase
Motor
Cable
Or AC for Scout
Motor Head Adapter
and WYE
Step-Up
Transformer
Figure 56. ESP System Diagram
ESP Downhole Choke and Sensor Module (Gauge) Pressure Measurement
The intake pressure measures the pressure inside the motor housing. Motor oil protects
the intake pressure port from well fluid contamination.
The discharge pressure measures the pressure at the pump discharge port via a
hydraulic line connection to the discharge port on the pump. This connection is available
only on Dual Pressure gauges such as the ESP-3500 and QESP-3500.