CHAPTER 3: ELECTRONIC CONTROL UNIT
3.1 CR/42/24 WIRING DIAGRAM
Page 8/16
PHOTOCELL
FOR CLOSURE
RECEIVER
TRANSMITTER
PEDESTRIAN
OPEN/CLOSE
SENSITIVE EDGE
CLOSURE LIMIT SWITCH
OPENING LIMIT SWITCH
DISCONNECT THE POWER
SUPPLY BEFORE WORKING
ON THE WIRING
GATE OPEN INDICATOR
LIGHT 24V MAX 50mA
FLASHING LIGHT
24V MAX 25W
SIN
C
E
1
96
5
M
E
R
C
U
R
IO
/5
2
4
A
I
E
NORMAL SPEED
Trimmer for motor speed adjustment
during normal working phase
3 - 4
Input for power supply of electronic board 20Vac via a toroidal
transformer (pre-wired red green/orange cables)
11 - 12
7 - 8
13 - 14
15
16
18
20
PHOTOCELL
FOR OPENING
OR SENSITIVE
EDGE
23
With dip SW2 OFF: input for photocell active during both opening and closure
(NC contact): if obscured during opening, the gate stops moving, but starts
again as soon as the photocell is clear; in closure it reverses the motion
With dip SW2 ON: input sensitive edge (NC contact): both in opening and
closure the gate reverses the motion by 10 cm
21 -17
FUSES:
F3 = T16A 250V
-power supply control unit-
F4 = F2A 250V
-main-
F1 = T1,6A 250V
-low voltage protection-
F2 = T16A 250V
-battery fuse-
-delayed-
-delayed-
-delayed-
+
-
NC
NO
NC
STOP
NO
NC
NC
NC
22
12
9
ANTENNA
GND
(SHEATH)
OPEN
CLOSE
1
2
3
4
5
6
7
8
F1F1
F2F2
2
5
2
4
START
PED
STOP
FOTO
FCA
FCC
DL8
+
-
E
N
C
O
D
E
R
PAUSA
LAVORO
PROG
F3F3
O
N
O
N
SW1
SW2
S
O
G
4
FOTO-1
+
-
V
E
L
O
C
IT
A
'
R
E
G
IM
E
V
E
L
O
C
IT
A
'
R
A
L
L
E
N
T
A
M
E
N
T
O
13
10
11
14
15
16
17
18
19
20
21
22
23
+
-
Batterie
12Vdc 1,2Ah
OPTIONAL
230V~ ±10%
50/60Hz
F
N
1A SLOW-ACTING
MAINS FUSE
F4
BROWN
BLUE
+
-
RED
GREEN or ORANGE
1 - 2
BATTERIES
Input for backup power supply for n. 2 batteries (in series) 12Vdc 1,2 Ah
(Type SERAI BT/14) battery charger included, 1
-
, 2
+
5 - 6
9 - 10
INDICATOR LIGHT
Gate open indicator light output 24Vdc max 50mA (
, 10
-
)
9
+
19
PHOTOCELL
FOR CLOSURE
Input for photocell active only in closure (NC contact): in closure the gate
reverses the motion
SLOW-DOWN SPEED
Trimmer for motor speed adjustment
during slow-down phase
+
-
BLACK (do not use)
YELLOW (do not use)
*
*
24
25
+
-
+
-
24 - 25
DL9
Batterie
12Vdc 1,2Ah
OPTIONAL
SOG/4A
Connector for any SOG/4A receiver
cards
ENCODER
Connector for encoder wiring
(If featured)
Sw1
Microswitches for control unit setting
Sw2
Microswitches for control unit setting
PROG
Button to enter programming mode
PAUSE
Button for gate open pause
Programming
WORK
Work programming button
DESCRIPTION
TERMINALS
CONNECTIONS
Courtesy light output. V
Active for 90 seconds from STOP
oltage free relay contact - 10A 250Vac-
Flashing light power supply output -max 25W- SERAI RZ/24F
FLASHING LIGHT
COURTESY LIGHT
MOTOR
Motor power supply 24Vdc output (5 = Closure 6 = Opening)
POWER SUPPLY
POWER SUPPLY
PHOTOCELLS
Power supply output
24Vdc
(
13=+, 14=-
)
for photocells
Opening limit switch (NC contact when gate is in an intermediate
position)
Closure limit switch (NC contact when gate is in an intermediate
position)
LIMIT SWITCH
(OPENING)
LIMIT SWITCH
(CLOSURE)
STOP
CONTROL
Stop control input (NC contact). When pressed, this control locks
out motor operation; if pressed during the gate open pause time,
it overrides the automatic reclosure
Input common terminals
INPUT
COMMON
PEDESTRIAN
CONTROL
OPEN/CLOSE
CONTROL
Input for antenna connection for built-in receiver (24=ANTENNA,
25=GND/
)
sheath
BUILT-IN
RECEIVER
ANTENNA
Pedestrian control input (NO contact). When pressed, this control
opens the gate by approx. 1 metre
N.B.
This function can be modified as described in "modify controls".
Open/close control input (NO contact) - this controls gate opening
and closure in the step-step mode
N.B.
This function can be modified as described in "modify controls".