CR/53 CONNECTIONS LAYOUT
NC
LIMIT SWITCH
CLOSING
MOTOR
T
E
R
M
IN
A
L
B
O
A
R
D
M
P
/3
0
M
O
T
O
R
10 11
1 2
3 4
5 6
7
8
9
F2
F2
F1F1
GND
(BRAID)
ANTENNA
+ -
NA
START
+
-
2 Batteries
12Vdc 2Ah
OPTIONAL
1
2
+
-
BATTERY
R
E
D
B
L
A
C
K
M1
W
H
IT
E
W
H
IT
E
230V~ ±10%
50/60Hz
F
N
12
F3F3
13
P1
DL1
230Vca
±
10% 50/60 Hz, Hz power supply input, which via fuse
F3 powers the primary of the toroidal transformer
- already wired -
Motor power supply 24Vdc output
Start control input (NO contact) controls the opening and closure
with inversion during movement.
Common input terminals
Input for the connection of the antenna for the built-in receiver. For
normal capacity, the calibrated wire already connected is sufficient.
(
10=BRAID/GND, 11=ANTENNA
)
20Vac-24Vdc input for power supply of the circuit board
supplied via a toroidal transformer- already wired-
Input for the connection of 2 12V 2Ah buffer batteries
(optionals, e.g. SERAI BT/20) to guarantee functioning of the
automation in the case of a power cut. In presence of the
circuit board network voltage, it recharges the batteries via the
built-in battery-charger.
Closure limit switch input (NC contact)
DEFINITION OF THE CLAMPS
CLAMPS
CONNECTIONS
DESCRIPTION
12 - 13
NETWORK
POWER SUPPLY
5 - 6
MOTOR
8
7
START
CONTROL
COMMON
INPUTS
10 - 11
BUILT-IN
RECEIVER
ANTENNA
9
3 - 4
TRANSFORMER
SECONDARY
INPUT
1 - 2
OPTIONAL
BATTERIES
CLOSURE
LIMIT SWITCH
!
DISCONNECT THE POWER SUPPLY
-FROM THE NETWORK AND THE
BATTERY ID PRESENT, BEFORE
INTERVENING ON THE CONNECTIONS
F1 = F5A
250Vca -instant-
-BOARD INPUT-
F2 = F5A
250Vca -instantaneous-
-BATTERY-
F3 = T1,6A
250Vca -delayed-
-PRIMARY TRANSFORMER-
D
AL
1
96
5
Pag. 5/7
K
IT
/4
5
I E