BEHAVIOUR WHEN
STRIKING AN OBSTACLE
FOLLOWING THE
INTERVENTION OF THE
MOTOR SHUTDOWN
CONTROL
during closing (up)
before limit switch
during opening
(moving down)
The motor stops and inverts for 0.25s.
The motor stops and inverts until completely open.
BATTERY FUNCTIONING
If there is a power cut, the system continues to function with the batteries, if they are connected, without any diffe-
rence in operation.
When the mains voltage returns, the built-in battery charger charges and maintains the batteries in this state.
24 hours are required for complete re-charging.
DELETING CODES IN THE MEMORY
The deleting of all radio codes memorised is carried out by pressing and holding the P1 key until the DL1 LED
switches off (about 10s) without sending any radio code.
LEARNING THE RADIO CONTROL CODE
The circuit board incorporates a 433.92 MHz radio receiver which allows to control the motor at a distance via
micro switch remote controls of the OG/02, OG/04 series and self-learning remote controls of the OG/62, OG/64,
OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84 series.
!
ATTENTION:
- before using a remote control, perform the programming procedure.
- a maximum of 10 codes can be memorised.
-
before starting first programming or deleting the remote controls, temporarily disconnect the
antenna to prevent the receiver from acquiring other signals during this phase, which may cause
incorrect functioning of the automation. Re-connect the antenna when the procedure has ended.
LEARNING START CODE
- With the control unit powered press the P1 key once to enter programming. The DL1 LED starts to flash to
indicate that the control unit is in the programming state.
- Press the remote control button (e.g. on the left) and hold down until the DL1 LED switches off. The control unit
has memorised the radio code received and automatically leaves programming, setting itself for normal
functioning.
- Repeat the procedure if several remote controls must be memorised.
12 3
4 5
6 7
8 9
10
12 3
4 5
6 7
8 9
10
!
MODIFY THE FACTORY
CONFIGURATION TO PREVENT
UNDESIRED CONTROLS
CONFIGURATION OF MICRO SWITCHES ONLY IN THE CASE OF OG/02 AND OG/04 REMOTE CONTROLS
Only if OG/02 and OG/04 remote controls with micro switches are used, before performing learning of the codes on
the receiver, the factory configuration of the micro switches must be modified to prevent undesired controls.
MOTOR SHUTDOWN CONTROL
The control unit has "shutdown motor" control able to intervene when the motor remains completely at a standstill
for a couple of seconds. It is a control that cannot be regulated or excluded which is used to identify stops and
motor blocks during the normal run.
.
STANDARD OPERATION OF MOTOR BOARD
- With the motor closed (upright position with limit switch active) a start control moves the motor down (opens).
- With the motor open (horizontal position with limit switch deactivated) a start control moves the motor up (closes).
- With the motor closing (moving up) a start control inverts motion until it opens completely.
- With the motor opening (moving down) a start control inverts motion until it closes completely.
- When fully opened/closed, there is a 0.25s motion inversion to reduce pressure and facilitate release.
- The 1st manoeuvre is closing (up) if the limit switch is not active, while it is opening (down) if the limit switch is active.
INDICATION OF RED DL1 LED
When the board switches on, the LED flashes twice.
Subsequent flashes indicate the reception of a radio signal or other various programming phases.
D
AL
1
96
5
Pag. 6/7
K
IT
/4
5