Find the installation position keeping in mind that the parking space
saver must remain below the car when parked.
If needed, make an adequate cement foundation to position the
parking space saver motor and arrange the arrival of the Ø=20mm
tube to pass the cables through the hole below the motor.
Using the base as a template, prepare 6 fixing holes using M8 screws
with dowels and fix the motor temporarily.
Remove the rear screw -A- and lift the casing -B- to access the
terminal board with the following connections:
red-black: 24Vdc motor
white-white: closing limit switch contact
Connect the power cables passing them through the underground
tube by means of the prepared inlet, below the motor, on the fixing
base.
Put the casing back in place and after connection to the control unit
make sure it works properly.
A
B
MANUAL RELEASE
MOTOR INSTALLATION
Unscrew the specific safety screw with a hex key from above or
by hand from below.
Remove the shear pin making sure the motor does not fall.
The motor is now released from the "gate" which can be moved
manually.
The pin can be used to position the gate back in the closed
position, inserting it into its side seat.
3 FIXING HOLES
ON EACH SIDE
CABLE INLET HOLE
BELOW MOTOR
TECHNICAL DATA OF MP/30 MOTOR
Power supply:
24Vdc ± 25%
Power and rated current:
24W - 1A
Moving time:
10s
Operating temperature:
-20°C ÷ +60°C
Weight: 14Kg