background image

BATTERY HOUSING AND CABLES INLET

Seats for fairleads PG11 and PG 13,5 which are easy to break through, are envisioned in the lower part of the container 
for the passage of input cables.

!

ATTENTION: Close all inlets well to 
prevent the entry of insects, which 
may damage the control unit.

Two strips are supplied complete with screws for fixing the two 12V 2 Ah batteries (SERAI BT/20) onto the lid of the 
container.

!

ATTENTION: Considering the weight 
of the batteries, it is recommended 
to install them at the end of 
mounting, before closing the box.

OPENING AND CLOSING THE BOX

When opening the box, make sure that most of the hinges 
escape from the guide on the bottom of the control unit in order 
to guarantee that the cover remains open without obstructing 
the control unit wiring operations.

In the closing phase, accompany the cover “especially in the 
presence of the battery” until complete return of the hinges. Pay 
attention that the gasket is inserted correctly. Close the cover 
using the appropriate screws.

FIXING THE CONTROL UNIT TO THE WALL

It is recommended to position the appliance in proximity 
of the parking space saver in a way to reduce the length 
of the connection cable, to the rest of the system, to a 
minimum. The control unit must be fixed via the cable 
passage holes facing downwards.

NO

NO

YES

Ø 6 ÷ 8 mm

Recommendations for connections in general environments according to the Italian Standard (IEC 64-8)

Upstream from the system, prepare an omnipolar isolating switch with distance of 3 mm or more between the 

contacts. As an alternative, use a 10A magnet circuit breaker switch.

2.   Make any type of connections always with the system not powered, i.e. with the isolating switch in the "open" position 

("0" symbol). In particular, the control unit must never be powered during wiring or while any expansion cards are 
being inserted.

.

1.

3. When installing the plant, use the following cables: 

- for the power supplies to the motors: minimum 1.5 mm2.
- for the power supplies of the battery: minimum 2.5 mm2.
- for the power supplies of the control unit: 1.5mm2   cross-section for maximum length of 19m, 2.5mm2   cross-       

section for lengths up to 31m.

- for low-voltage and current lines, such as control buttons: 0.5mm2   cross-section for maximum length of 50m, 

0.75mm2   cross-section for lengths up to 100m.

10 11

1 2

3 4

5 6

7

8

9

F2

F2

F1F1

+ -

BATTERY

P1

DL1

F3F3

D

AL

  1

96

5

Pag. 4/7

K

IT

/4

I E

Summary of Contents for KIT 45

Page 1: ...on of its own products SERAI has respected the following Reference Directives for CE marking machinery 2006 42 EEC low voltage 2006 95 EEC electromagnetic compatibility 2004 108 EEC General reference...

Page 2: ...e by means of the prepared inlet below the motor on the fixing base Put the casing back in place and after connection to the control unit make sure it works properly A B MANUAL RELEASE MOTOR INSTALLAT...

Page 3: ...en the lid from the opposite side proceed as follows ATTENTION This operation must be carried out before fixing the container to the wall Insert a flat tip screwdriver into the fixing recess of the hi...

Page 4: ...ance in proximity of the parking space saver in a way to reduce the length of the connection cable to the rest of the system to a minimum The control unit must be fixed via the cable passage holes fac...

Page 5: ...ac 24Vdc input for power supply of the circuit board supplied via a toroidal transformer already wired Input for the connection of 2 12V 2Ah buffer batteries optionals e g SERAI BT 20 to guarantee fun...

Page 6: ...s the remote control button e g on the left and hold down until the DL1 LED switches off The control unit has memorised the radio code received and automatically leaves programming setting itself for...

Page 7: ...ussubstancesinelectricalandelectronicequipment aswellaswastedisposal This device was manufactured after 13 08 2005 The symbol of the crossed out wheeled bin applied on the device itself or on its pack...