Sentry Equipment Corp

equipment from road dirt and damage, or in case of electric drive motors for pumps, from excessive exposure to 

cleaning sprays . 

Select a location to install the sampler where the material in the process stream is well mixed . Location of the sampler 

and controller is very important for accurate sampling results . They should be as close together as practical, within 

sight of each other, and protected from weather, traffic damage and normal work activities in the area .

When selecting a sampler location, ensure the sample collection container will clear vertical lines (or other 

obstructions) when mounted onto the sampler . The sampler can be used on a pipe or tank running horizontally, 

vertically or at an angle, but the axis of the sampler body must be horizontal .

Sampler Installation 

Install the sampler by using a line mounting tee that positions the sampler nose (front of body) close to the main 

sample flow stream . In this position, samples are taken directly from moving product . A short 1-1/2-inch ferrule clamp 

port on the side of the adapter tee (as recommended and/or furnished by Sentry Equipment Corp) provides the 

proper line mounting location for the sampler .

If a standard Sentry adapter tee cannot be used, a 1-1/2-inch tri-clamp style ferrule clamp port must be devised . The 

ferrule branch should be just long enough to accept the sampler mounting clamp without interference . The factory 

standard is 5/8-inch from the ferrule face to the outside of the line .

Refer to your system application drawing included with this manual and the following section in this manual to install 

the sampler controller in its most effective location .

1. 

The line where the sampler is to be located can be horizontal, vertical or at any angle . The location selected must 

mount the sampler body with its long axis horizontal and with sufficient clearance beneath the unit for ease of 

sample container mounting and exchange .

2. 

Disconnect the piping, insert the sampler mounting tee, and reconnect the piping to the tee . Attach the sampler 

to the short 1-1/2-inch tri-clamp ferrule port on the tee with the clamp and gasket .

3. 

Check to ensure the sampler body is horizontal . Loosen the tee and rotate it if required . Install the air line to the 

fitting on the sampler barrel . Use 36 inches of the length of 1/4-inch OD flexible polyurethane tubing provided .

4. 

Press the tube end over the barb fitting by hand . No external clamps are needed . Use no more than 36 inches 

of connecting airline; shorter if practical . Remember, the sampler must be removed from the piping for daily 

cleaning . Air lines longer than 36 inches may restrict the sampler’s maximum cycle rate .

5. 

If a bag or vial adapter will be used, insert the o-ring seal into the sampler body port . It seats into a groove above 

the threads . Screw the adapter into the 24 mm threaded discharge port of the sampler . Turn in firmly, by hand . DO 

NOT USE TOOLS . Excess force could bind or gall stainless threads .

Controller Installation

Refer to your system application plus the controller group drawings included with this manual .

Select a location in an equipment cabinet, preferably a “dry” compartment area where using the sampler controller will 

be convenient for the operator, yet protected from direct exposure to cleaning solutions or wash water sprays .

Avoid positioning the sampler controller in any location where milk, water, cleaning solutions,  

tools, etc . could cause damage .

Summary of Contents for ISOLOK MSA

Page 1: ...Original Instructions Installation Operation Maintenance Manual ISOLOK MSA Sampler Point Samplers S AS IOM 00300 8 10 22...

Page 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Page 3: ...Controller Installation 8 Inspection 11 Operation 11 Initial Cleaning 11 Starting the Sampler 11 Maintenance 12 Daily Cleaning 12 Weekly Inspection 13 Complete Sampler Disassembly and Maintenance 13 C...

Page 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Page 5: ...at the equipment is isolated from all connecting piping the equipment is depressurized the contents have been drained and the equipment is cool Moving parts This equipment may contain moving parts All...

Page 6: ...se or piping to pass the sampler before operation begins During initial delay the controller solenoid valve is energized causing the sampler plunger to extend into the mounting tee where it can be flu...

Page 7: ...y plastic bags that close with a built in wire tie Sizes up to about an 8 oz 250 ml capacity can be supported by carefully folding the open bag mouth and wire around the small diameter below the drip...

Page 8: ...sampler controller in its most effective location 1 The line where the sampler is to be located can be horizontal vertical or at any angle The location selected must mount the sampler body with its l...

Page 9: ...ed around a sealing bulkhead wall without the danger of pinching the tube or blocking the door Wall Penetrations The following procedure is suggested whenever air tube must be routed through a wall be...

Page 10: ...miting device This device automatically disconnects power to the controller in the event of an accidental overload or short circuit Identified as AutoFuse this device opens the power circuit any time...

Page 11: ...After installation the sampler periodically should be checked for proper operation and to ensure that any wear is detected so proper preventive maintenance can be performed The Maintenance section of...

Page 12: ...knob with a screwdriver in the slot provided 2 Start delay adjustment 0 1 10 seconds 3 Turn clockwise to increase counterclockwise to decrease delay 4 Start delay is a single turn potentiometer It wi...

Page 13: ...r body to compress the spring Install the clamp Replace any port adapter including the O ring seal 10 Replace the line tee gasket and install the sampler and clamp in place The sampler body should be...

Page 14: ...mble the four plunger seals rod seal and piston seal O rings onto the plunger 2 Apply a thin film of the approved dairy lubricant to all six seals Assemble the spring onto the plunger and insert it in...

Page 15: ...roller sample rate potentiometer is a round component with brown wire leads on two of three lugs If controller operation becomes erratic e g cycles at some load size dial settings but not at others or...

Page 16: ...alve using the following steps 1 Disconnect the air line tubing to the sampler Disconnect the incoming compressed air supply line Open the sampler controller enclosure Disconnect the wire leads betwee...

Page 17: ...y monitor and measure processes for improved production efficiency output and safety Standing behind our commitments we are determined to tackle any application anywhere We know that running an effici...

Page 18: ...r combining both into one connection and using the remaining pin for the sampler power lead AC Power Supply Package This parts package is used with 230 VAC supply and rectifies and transforms 230 VAC...

Page 19: ...ation NOTE Within the motor junction box either T5 or T8 normally will be connected to T2 and T3 Select a combination of motor leads so that the sampler is NOT wired into this connection Polarity The...

Page 20: ...d U S Dept of Transportation or equal for service to at least 120 psi 827 KPa Tanks can be obtained locally from firms that build or repair truck air brake systems or an air tank package is available...

Page 21: ...roduces less than 1 U S ounce 30 cc or 60 sampler cycles A biased sample could result 3 Select a sample container size that will not be filled completely even on longest sampling times Use care in set...

Page 22: ...inute etc actual delivery will be influenced by many factors some of which are Speed of pump drive and pump condition Type of valve on farm tank Suction hose size and condition Head pressure suction a...

Page 23: ...ISOLOK MSA Sampler 23 This page is intentionally left blank...

Page 24: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Reviews:

Related manuals for ISOLOK MSA