background image

18 

Sentry Equipment Corp

Appendix: Installation & Operation on a Milk Truck

Sampler and Controller Installation

Please see the “Installation” section of this manual for general installation and sampler controller installation 

instructions .

When selecting a location on a milk truck, a typical location is on the ceiling or side wall of the motor compartment, as 

close to the sampler location as possible . Otherwise, follow the general controller installation instructions .

Electrical Power Connection

Please see page 10 of this manual for general electrical power connection . The following is specific to power 

connection on a milk truck .

This parts package is used with a 12 volt power supply . Install this electrical supply using the following steps:

1. 

Attach insulated, stranded wire (No . 18 AWG or larger) to a non-switched terminal, such as a non-grounded battery 

terminal or equivalent .

2. 

Run wire lead to the 1/4 in spade-type terminal [+] on back of the cycle controller . Route wire along chassis to give 

it protection from accidental damage .

3. 

Semi-trailer units will require a disconnect between the tractor and trailer . If the existing disconnect has an unused 

pin, run the power lead through this pin . Alternately, if two pins are used for similar circuits (e .g ., left clearance 

lights on one pin, right side on another), consider combining both into one connection and using the remaining 

pin for the sampler power lead .

AC Power Supply Package

This parts package is used with 230 VAC supply and rectifies and transforms 230 VAC to 12 VDC (at 1/2 amp) to supply 

the sampler controller . Interlocking to 230 VAC electrical service also automates the “start-stop” sampling function . 

Disconnect any 230 volt power supply from the truck before making any electrical connections .

Install the AC electrical supply using the following steps:

1. 

Locate the power supply in an equipment cabinet convenient to both the sampler controller and pump motor 

reversing switch . The power connection is a 36-inch length of flexible SJO cord, complete with metallic fitting and 

conduit lock-nut .

2. 

Mount the power supply using two brackets attached, or remove the cover to locate mounting holes within the 

enclosure using your drawing as a template . Drill holes to accept fasteners selected and secure the power supply 

enclosure .

3. 

Examine the motor conduit box or motor drum switch . The power cord fitting is mounted through a 1/2-inch 

conduit knock-out . If none can be found, a 7/8-inch diameter hole can be drilled or punched through the conduit 

box or drum switch cover, whichever allows a clean mounting of the power supply connector without becoming 

an obstruction .

4. 

Insert the wires and cord connector through the hole and place a conduit nut on the fitting, locking firmly . 

PROVIDE A SUITABLE GROUND CONNECTION TO POWER SUPPLY . Check ground continuity after mounting .

Summary of Contents for ISOLOK MSA

Page 1: ...Original Instructions Installation Operation Maintenance Manual ISOLOK MSA Sampler Point Samplers S AS IOM 00300 8 10 22...

Page 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Page 3: ...Controller Installation 8 Inspection 11 Operation 11 Initial Cleaning 11 Starting the Sampler 11 Maintenance 12 Daily Cleaning 12 Weekly Inspection 13 Complete Sampler Disassembly and Maintenance 13 C...

Page 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Page 5: ...at the equipment is isolated from all connecting piping the equipment is depressurized the contents have been drained and the equipment is cool Moving parts This equipment may contain moving parts All...

Page 6: ...se or piping to pass the sampler before operation begins During initial delay the controller solenoid valve is energized causing the sampler plunger to extend into the mounting tee where it can be flu...

Page 7: ...y plastic bags that close with a built in wire tie Sizes up to about an 8 oz 250 ml capacity can be supported by carefully folding the open bag mouth and wire around the small diameter below the drip...

Page 8: ...sampler controller in its most effective location 1 The line where the sampler is to be located can be horizontal vertical or at any angle The location selected must mount the sampler body with its l...

Page 9: ...ed around a sealing bulkhead wall without the danger of pinching the tube or blocking the door Wall Penetrations The following procedure is suggested whenever air tube must be routed through a wall be...

Page 10: ...miting device This device automatically disconnects power to the controller in the event of an accidental overload or short circuit Identified as AutoFuse this device opens the power circuit any time...

Page 11: ...After installation the sampler periodically should be checked for proper operation and to ensure that any wear is detected so proper preventive maintenance can be performed The Maintenance section of...

Page 12: ...knob with a screwdriver in the slot provided 2 Start delay adjustment 0 1 10 seconds 3 Turn clockwise to increase counterclockwise to decrease delay 4 Start delay is a single turn potentiometer It wi...

Page 13: ...r body to compress the spring Install the clamp Replace any port adapter including the O ring seal 10 Replace the line tee gasket and install the sampler and clamp in place The sampler body should be...

Page 14: ...mble the four plunger seals rod seal and piston seal O rings onto the plunger 2 Apply a thin film of the approved dairy lubricant to all six seals Assemble the spring onto the plunger and insert it in...

Page 15: ...roller sample rate potentiometer is a round component with brown wire leads on two of three lugs If controller operation becomes erratic e g cycles at some load size dial settings but not at others or...

Page 16: ...alve using the following steps 1 Disconnect the air line tubing to the sampler Disconnect the incoming compressed air supply line Open the sampler controller enclosure Disconnect the wire leads betwee...

Page 17: ...y monitor and measure processes for improved production efficiency output and safety Standing behind our commitments we are determined to tackle any application anywhere We know that running an effici...

Page 18: ...r combining both into one connection and using the remaining pin for the sampler power lead AC Power Supply Package This parts package is used with 230 VAC supply and rectifies and transforms 230 VAC...

Page 19: ...ation NOTE Within the motor junction box either T5 or T8 normally will be connected to T2 and T3 Select a combination of motor leads so that the sampler is NOT wired into this connection Polarity The...

Page 20: ...d U S Dept of Transportation or equal for service to at least 120 psi 827 KPa Tanks can be obtained locally from firms that build or repair truck air brake systems or an air tank package is available...

Page 21: ...roduces less than 1 U S ounce 30 cc or 60 sampler cycles A biased sample could result 3 Select a sample container size that will not be filled completely even on longest sampling times Use care in set...

Page 22: ...inute etc actual delivery will be influenced by many factors some of which are Speed of pump drive and pump condition Type of valve on farm tank Suction hose size and condition Head pressure suction a...

Page 23: ...ISOLOK MSA Sampler 23 This page is intentionally left blank...

Page 24: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Reviews: