background image

ISOLOK MSA Sampler 5

General Safety Precautions

Product Selection, Installation, and Use

Improper selection, installation, or use can cause personal injury or property damage. It is solely the responsibility of users, 

through their own analysis and testing, to select products suitable for their specifi c application requirements, ensure they are 

properly maintained, and limit their use to their intended purpose.
Follow proper local, state, and federal regulations for proper installation and operational requirements.
Always use caution and common sense when working with any chemical. Read the product label and Material Safety Data 

Sheets (MSDS) carefully and follow the instructions exactly.

Potential Equipment Hazards

Hot surfaces!

 This equipment may have very hot surfaces. If an operator contacts a hot surface, injury may occur. Use 

protective clothing to prevent injury. If other equipment comes in contact with a hot surface, damage to the equipment may 

occur. Ensure the area around this equipment is kept clear to prevent damage from occurring.

High pressures!

 This equipment may contain fl uids at very high pressures. Prior to installing, removing or maintaining this 

equipment, ensure that the equipment is isolated from all connecting piping, the equipment is depressurized, the contents 

have been drained, and the equipment is cool.

Moving parts!

 This equipment may contain moving parts. All drive guards and doors must be secured in place when this 

machine is being operated.

Equipment rated TX. Equipment maximum surface temperature depends 

on operating conditions. Ensure maximum surface temperature shall stay 

below ignition temperature of dust or gas atmosphere where it is installed 

based on process conditions. Failure to comply could result in an explosion, 

causing serious injury or death to personnel and damage to equipment.
If the sampler is mounted directly to a non-electrically conductive surface, 

sampler shall be bonded to a grounding electrode. Failure to comply 

could result in sparking, which could lead to an explosion, causing harm to 

personnel and equipment.
If the sample container is removed from the sampler, do not insert any 

body part or other item into the sample discharge port. Crushing will 

occur. 

To ensure proper sampler operation, be sure 

the sampler is installed in a pipe large enough 

for the sampler plunger to extend without 

impacting the pipe. Failure to comply will 

result in equipment damage and poor sample 

quality.

Sampler may require a two-person lift. Please 

refer to the General Arrangement drawing for 

weight and dimensional information. 

Summary of Contents for ISOLOK MSA

Page 1: ...Original Instructions Installation Operation Maintenance Manual ISOLOK MSA Sampler Point Samplers S AS IOM 00300 8 10 22...

Page 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Page 3: ...Controller Installation 8 Inspection 11 Operation 11 Initial Cleaning 11 Starting the Sampler 11 Maintenance 12 Daily Cleaning 12 Weekly Inspection 13 Complete Sampler Disassembly and Maintenance 13 C...

Page 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Page 5: ...at the equipment is isolated from all connecting piping the equipment is depressurized the contents have been drained and the equipment is cool Moving parts This equipment may contain moving parts All...

Page 6: ...se or piping to pass the sampler before operation begins During initial delay the controller solenoid valve is energized causing the sampler plunger to extend into the mounting tee where it can be flu...

Page 7: ...y plastic bags that close with a built in wire tie Sizes up to about an 8 oz 250 ml capacity can be supported by carefully folding the open bag mouth and wire around the small diameter below the drip...

Page 8: ...sampler controller in its most effective location 1 The line where the sampler is to be located can be horizontal vertical or at any angle The location selected must mount the sampler body with its l...

Page 9: ...ed around a sealing bulkhead wall without the danger of pinching the tube or blocking the door Wall Penetrations The following procedure is suggested whenever air tube must be routed through a wall be...

Page 10: ...miting device This device automatically disconnects power to the controller in the event of an accidental overload or short circuit Identified as AutoFuse this device opens the power circuit any time...

Page 11: ...After installation the sampler periodically should be checked for proper operation and to ensure that any wear is detected so proper preventive maintenance can be performed The Maintenance section of...

Page 12: ...knob with a screwdriver in the slot provided 2 Start delay adjustment 0 1 10 seconds 3 Turn clockwise to increase counterclockwise to decrease delay 4 Start delay is a single turn potentiometer It wi...

Page 13: ...r body to compress the spring Install the clamp Replace any port adapter including the O ring seal 10 Replace the line tee gasket and install the sampler and clamp in place The sampler body should be...

Page 14: ...mble the four plunger seals rod seal and piston seal O rings onto the plunger 2 Apply a thin film of the approved dairy lubricant to all six seals Assemble the spring onto the plunger and insert it in...

Page 15: ...roller sample rate potentiometer is a round component with brown wire leads on two of three lugs If controller operation becomes erratic e g cycles at some load size dial settings but not at others or...

Page 16: ...alve using the following steps 1 Disconnect the air line tubing to the sampler Disconnect the incoming compressed air supply line Open the sampler controller enclosure Disconnect the wire leads betwee...

Page 17: ...y monitor and measure processes for improved production efficiency output and safety Standing behind our commitments we are determined to tackle any application anywhere We know that running an effici...

Page 18: ...r combining both into one connection and using the remaining pin for the sampler power lead AC Power Supply Package This parts package is used with 230 VAC supply and rectifies and transforms 230 VAC...

Page 19: ...ation NOTE Within the motor junction box either T5 or T8 normally will be connected to T2 and T3 Select a combination of motor leads so that the sampler is NOT wired into this connection Polarity The...

Page 20: ...d U S Dept of Transportation or equal for service to at least 120 psi 827 KPa Tanks can be obtained locally from firms that build or repair truck air brake systems or an air tank package is available...

Page 21: ...roduces less than 1 U S ounce 30 cc or 60 sampler cycles A biased sample could result 3 Select a sample container size that will not be filled completely even on longest sampling times Use care in set...

Page 22: ...inute etc actual delivery will be influenced by many factors some of which are Speed of pump drive and pump condition Type of valve on farm tank Suction hose size and condition Head pressure suction a...

Page 23: ...ISOLOK MSA Sampler 23 This page is intentionally left blank...

Page 24: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Reviews: