29
Installation instructions for trained electricians only
6
Continued
Error description:
Relays wobble
Unit turns on too early.
Unit turns on too late.
Unit does not turn on at all.
Determined system deviation ____ °C.
The set temperature is not kept constant.
Disturbing sounds come from the control.
The interior lighting does not light.
The fan control (speed) is defective.
ERROR number___ is indicated on the display.
The temperature fuse has been triggered unex-
pectedly.
Heater is turned off
Error occurs immediately after turning on.
Error occurs after it has been turned on for a while.
Operating unit can not be operated as intended.
Miscellaneous:
______________________________________
______________________________________
______________________________________
______________________________________
7
Changing Light fuse, the optional
fan and the unit electronics -
Figure
1
WARNING - Electric shock
Disconnect all poles of the sauna control
from the mains and secure from unintentio-
nal switching on prior to opening the cover
of the housing.
1. Slightly push in safety lock
5
and remove the
cover of the housing
6
.
2. Figure
2
: Release six-pin flat strip wiring
3
and
remove from connector
2
.
3. Carefully remove cover
2
from base of housing
7
.
4. Fuse for interior lighting
Replace (miniature fuse 5x20 T2.0 A/ 250V)
A
or
fuse for fan
(subminiature fuse TR 5 - T 1.0 A/ 250V)
8
or
fuse for unit electronics
(miniature fuse 5x20 T630 mA/ 250V)
B
.
5. Insert strips
3
of cover
2
into both holding fix-
tures
4
on the sides and carefully push down on
the base of housing
7
.
6
Check function of both switches
C
. (On and off
position)
7. Figure
2
: Push six-pin flat wire strip
3
on con-
nector
2
until you can hear the lock lever snap
in position (lock lever points downwards).
8. Fit the housing cover
6
on the base of the hou-
sing
7
, rotate it downwards and push down on
it until you can hear it lock in position.
Check for secure fit of housing cover.