![Sentek RT6 Hardware Manual Download Page 90](http://html.mh-extra.com/html/sentek/rt6/rt6_hardware-manual_1244388090.webp)
SENTEK
Page 86
communication with computer
Compatibility
The RT6 Main Board is a direct replacement for the
RT5 Main Board (only with receiver).
The RT6 will work with probe runs having 4-wire
boards with transmitters.
Caution:
Connecting probe runs with 4-wire boards (no
transmitters) to the RT6 Main Board may cause
damage to components.
Removable Logger firmware revision
The RT5 logger will work with the RT6 Main Board
and the RT6 logger will work with the RT5 Main
Board.
However the logger must be RT6 version (with RT6
Main Board) to enable remote telemetry via multi-
drop RS485 or radio.
Only RT6 logger model MRT6.3 with firmware
RTtype991111 supports all RT6 system features.
Features of earlier versions can be viewed on the
Sentek Web site Support > FAQ's > Version Table >
RT5 / RT6 Loggers.
IrriMAX software will work with RT5 loggers.
Comparison of 4-wire and 5-wire board
The 5-wire board is the combination of the circuitry
of the 4-wire board and transmitter. In addition to this
the 5-wire board has resetable fuses to resist damage
if a surge occurs during sampling. These fuses
automatically reset themselves when power is
removed (between sampling).
Compatibility
Probes with 5-wire boards can be mixed on a probe
run with probes having 4-wire boards (only with
transmitters).
EasyAG only support 5-wire boards.
Caution:
Probes on a run with 5-wire boards will not work
with probes on the same run with 4-wire boards
(without transmitters). Damage to components may
occur if connected together on the same run.
Summary of Contents for RT6
Page 1: ...Sentek RT6 HARDWARE MANUAL Version 3 2 February 2011 ...
Page 2: ......
Page 4: ......
Page 8: ...SENTEK Page 4 ...
Page 30: ...SENTEK Page 26 ...
Page 46: ...SENTEK Page 42 ...
Page 50: ...SENTEK Page 46 ...
Page 62: ...SENTEK Page 58 ...
Page 63: ...APPENDIX A Page 59 APPENDIX A System Overview ...
Page 64: ...SENTEK Page 60 ...
Page 65: ...APPENDIX B Page 61 APPENDIX B System configuration examples ...
Page 66: ...SENTEK Page 62 ...
Page 67: ...APPENDIX C Page 63 APPENDIX C Probe configuration examples ...
Page 68: ...SENTEK Page 64 ...
Page 69: ...APPENDIX D Page 65 APPENDIX D Front panel visual ...
Page 70: ...SENTEK Page 66 ...
Page 71: ...APPENDIX E Page 67 APPENDIX E Overlay diagram RT6 Main Board Overlay ...
Page 72: ...SENTEK Page 68 ...
Page 73: ...APPENDIX F Page 69 APPENDIX F Cable Wiring Order 5 wire Connector ...
Page 74: ...SENTEK Page 70 ...
Page 78: ...SENTEK Page 74 ...
Page 80: ...SENTEK Page 76 ...
Page 82: ...SENTEK Page 78 ...