![Sentek RT6 Hardware Manual Download Page 43](http://html.mh-extra.com/html/sentek/rt6/rt6_hardware-manual_1244388043.webp)
CHAPTER 5: OPERATING INSTRUCTIONS
Page 39
Chapter 5: Operating Instructions
Initial logger configuration and normalization
It is recommended to configure the RT6 Logger and
assemble the sensors and normalize them in an office
environment before installation of the probe in the
field.
The software in the logger must be configured to
match the probe configuration assembled for this
Sentek RT6 System. This involves:
1.
In IrriMAX, setup the database using the Logger
Configuration dialog then click "Send to RT6" to
put the configuration in the logger. This specifies
the Logger Id, sampling interval, probe and
sensor configuration on Run A and Run B and
communication baud rate.
2.
Then using the Logger Configuration dialog,
normalize the sensors in each probe.
3.
Using Logger Manager to set the logger wake up
times.
This process is described in the Logger Configuration
section of the IrriMAX manual and in the Logger
Manager manual.
Day-to-Day Operation
Note:
Once installed the Sentek RT6 System will operate
continuously without requiring the user to perform
any regular ongoing tasks.
The logger will store readings taken by the sensors
and hold these readings in its memory until cleared by
the user or overwritten by the logger itself.
The logger memory will only hold a certain amount
of data before the memory “wraps” and the oldest
data is overwritten with newer data. Refer to
Appendix J – Formula to Calculate Logger Storage
Capacity to determine the time before readings are
overwritten in the logger memory.
Summary of Contents for RT6
Page 1: ...Sentek RT6 HARDWARE MANUAL Version 3 2 February 2011 ...
Page 2: ......
Page 4: ......
Page 8: ...SENTEK Page 4 ...
Page 30: ...SENTEK Page 26 ...
Page 46: ...SENTEK Page 42 ...
Page 50: ...SENTEK Page 46 ...
Page 62: ...SENTEK Page 58 ...
Page 63: ...APPENDIX A Page 59 APPENDIX A System Overview ...
Page 64: ...SENTEK Page 60 ...
Page 65: ...APPENDIX B Page 61 APPENDIX B System configuration examples ...
Page 66: ...SENTEK Page 62 ...
Page 67: ...APPENDIX C Page 63 APPENDIX C Probe configuration examples ...
Page 68: ...SENTEK Page 64 ...
Page 69: ...APPENDIX D Page 65 APPENDIX D Front panel visual ...
Page 70: ...SENTEK Page 66 ...
Page 71: ...APPENDIX E Page 67 APPENDIX E Overlay diagram RT6 Main Board Overlay ...
Page 72: ...SENTEK Page 68 ...
Page 73: ...APPENDIX F Page 69 APPENDIX F Cable Wiring Order 5 wire Connector ...
Page 74: ...SENTEK Page 70 ...
Page 78: ...SENTEK Page 74 ...
Page 80: ...SENTEK Page 76 ...
Page 82: ...SENTEK Page 78 ...