No.11S098-03
40
STC-GE33OX/GEC33OX
Users guide Rev. 1.03
5.3.2 Exposure timing with the positive polarity trigger signal
Note.1: The trigger signal is removed by the filtering if the pulse width of the input trigger signal is less than 30
CLK
Please input the trigger signal has more then 31 CLK pulse width.
Note.2: The exposure is going to start 75 CLK after the rising edge of the trigger signal.
5.3.3 Exposure timing with the negative polarity trigger signal
Note.1: The trigger signal is removed by the filtering if the pulse width of the input trigger signal is less than 30
CLK
Please input the trigger signal has more then 31 CLK pulse width.
Note.2: The exposure is going to start 75 CLK after the rising edge of the trigger signal.
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure time: T1' = Preset exposure time
Filtering *Note.1
30CLK
Trigger signal
(With Photocoupler delay)
Less than
5 useconds
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure time: T1' = Preset exposure time
Filtering *Note.1
30CLK
Trigger signal
(With Photocoupler delay)
Less than
60 useconds