Senstar LM100 calibration
Page 56
Senstar LM100 Product Guide
The Head Sequence list is used to setup segments and zones. To be a part of a segment, the
position numbers of the heads must be sequential. For example, if six heads in the Ordered Heads
list will make up a segment covering the South-West section of fence, then the six heads must be
sequential in the Head Sequence list.
1.
Select the first luminaire from the Ordered Heads list and move it to the Heads Sequence
column by selecting the double arrow button.
2.
Select the second (sequential) luminaire from the Ordered Heads list and move it to the Head
Sequence column by selecting the double arrow button.
3.
Continue this process until all of the heads are moved to the Head Sequence table in the
desired order.
4.
If necessary, move the heads around the Head Sequence list by selecting a head and using
the up down arrows to move the selected head’s position in the list.
5.
Once the heads are organized in the Head Sequence list according to the site plan’s
requirements for luminaire segments and zones, close the Define Head Sequence window
and select the Yes button to save the changes.
6.
Save the UCM file and download the configuration changes to the LM100 gateway.
Senstar LM100 calibration
When calibrating the Senstar LM100 for the first time, begin with the detection parameters in the
default settings.
The Sensitivity Profile
A Sensitivity Profile should be recorded for the full length of the protected fence. The Sensitivity
Profile records each luminaire’s measured response to a consistent fence disturbance. The profile
will verify the luminaire’s detection performance and can identify problems on the fence, or
problems with a luminaire’s attachment.
Figure 51: Define Head Sequence window (Head Sequence)
Note
Once the segment and zone assignments are made on the Config tab,
the Head Sequence table will include the segment and zone information
with the heads that are assigned to them.
select a head from the Ordered Heads list
select the double arrow button to move the
the highlighted head is moved to the next
(the head will be highlighted in blue)
highlighted head to the Head Sequence list
position in the Head Sequence column
use the up/down arrows to move a head
up or down in the Head Sequence list
use the indicate button to activate a head
use the radio buttons to select the position
in the list for a highlighted head
(the selected head will flash 5 times)