The Universal Configuration Module
Page 48
Senstar LM100 Product Guide
Duration (min)
The number of minutes the activated luminaires will remain in alarm
mode following an alarm (1 - 15 minutes)
Light Level
Set the
Light Level
(brightness) for alarm response light activation
Zones sub-panel - luminaire Segment settings, Zone assignments and Relay assignments
Segment
The
Segment
field indicates the properties of the currently selected
Segment
; The listed properties apply to the selected
Segment
(Zone, Head, Relay, Profile, Threshold); The selected
Segment
is
shown with a white background on the segment display panel; One
or more numerically sequential heads can be assigned to a
Segment
; The LM100 system supports up to 50
Segments
Zone
Specify the
Zone
to which the selected
Segment
is assigned;
Multiple
Segments
can be assigned to one
Zone
; The LM100
system supports up to 50
Zones
Relay
(Local Control mode)
Specify the
Relay
which will activate in response to an alarm
condition in the selected zone
Head
Specify the first
luminaire
in the selected segment
Sequence button
The
Sequence
button is used to setup and define the physical
locations of the installed luminaires to create segments and zones
Profile button
The Sensitivity
Profile
records the detection signal response
magnitude for each luminaire based on a similar disturbance along
the full length of the protected fence
Split button
Select the
Split
button to divide the currently selected segment into
two equal segments
Delete button
Select the
Delete
button to merge the currently selected segment
with the preceding segment
Schedule tab - setup automatic lighting controls for the defined luminaire zones; time ON
(schedule starts) time OFF (schedule ends) Zone, Level - 3 brightness level selections prioritized
from lowest to highest (i.e., Level 1, Level 2, force Off)
SD Card tab - select the type of data that will be saved to an SD card on the LM100 gateway,
troubleshooting feature
Aux Cfig tab - setup the method of control and the I/O response (see
Aux Control
Select
Local
to have the I/O controlled by the gateway;
Select
Remote
to have the I/O controlled by the host security
management system
Aux Option Card
Select
Input
if the processor includes an optional input card;
Select
Output
if the processor includes an optional output card
Aux type
Specify each of the ten I/O ports as either an
Input
or
Output
Input Configuration
Setup the gateway’s inputs and the optional input card’s 4 inputs
Output Configuration
Setup the gateway’s relay outputs and the optional output card’s 4
outputs
Network Cfig tab - setup the Silver Network communication parameters
GSM Cfig tab - setup the detection parameters for the Senstar Wireless Gate Sensor
GSM Status tab - review the status of up to four Wireless Gate Sensor Modules
Remote Cfig tab - used for Senstar LM100s that are reporting alarms and supervision conditions
through an UltraLink I/O system operating in Network Manager mode; specify outputs that will
activate in response to alarm and supervision conditions
Configuration parameter
Descriptions