SU320CSX
4110-0446, Rev. C
Page 61 of 96
© 2017 UTC
Aerospace Systems
Date Printed: 3-Jan-2017
This document does not contain any export controlled technical data.
Parameters
none
Return Values
mode
Range
0
Internally triggered, internally timed
1
Externally triggered, internally timed
2
Externally triggered, externally timed
3
Externally gated, internally timed
Type
unsigned integer
Example
TRIG:MODE? -- query command
1
-- return value
5.13.3.
Set Trigger Source Mode
Description
Sets the trigger source mode. The camera can accept triggers from
the Camera Link CC1 signal as well as the Trigger port in the
AUX/POWER connector. Note: Execution of this command that
results in a change in trigger source will also apply a reset to the
trigger and FPA scan digital logic clearing any existing trigger or
scan errors.
Setting Type
Global
Command
TRIG:SOURCE
value
Parameters
value
Return Values
none
Range
0 – 3
0
None
1
Camera Trigger Port
2
Camera Link CC1
3
Either Camera Trigger Port ‘OR’ CC1 (‘AND’ function not
enabled)
Type
unsigned integer
Example
TRIG:SOURCE 2
5.13.4.
Get Trigger Source Mode
Description
Returns the trigger source mode.
Setting Type
Global
Command
TRIG:SOURCE?
Parameters
none