Return Values
opr_setting
Range
0 to (number)
Type
unsigned integer
Example
AGC:OPR:LOW? -- query command
0 -- return value
5.9.5.
Set AGC High Operational Setting
Description
This command used in conjunction with the set AGC low
operational setting defines the range of operational settings that are
available for use by the AGC algorithm. In this tool, high refers to
the numerical value, i.e. 5 is higher than 4, and is not relative to
light levels. WARNING: If the AGC high operational bound is set
lower than the current AGC low operational bound, the camera
AGC operation is no longer specified.
Setting Type
Global
Command
AGC:OPR:HIGH
opr_setting
Parameters
opr_setting
Return Values
none
Range
0 to (number), limited by number of operational settings that
currently exist.
Type
unsigned integer
Example
AGC:OPR:HIGH 14
5.9.6.
Get AGC High Operational Setting
Description
Returns the highest operational setting available for use by the AGC
algorithm
Setting Type
Global
Command
AGC:OPR:HIGH?
Parameters
none
Return Values
opr_setting
Range
0 to (number) limited by number of operational settings that
currently exist.
Type
unsigned integer
Example
AGC:OPR:HIGH? -- query command
7 -- return value