Setting up the conference system
Setting up a large wired conference system
For conference systems comprising more than 40 conference units or when the
conference units are connected in a redundant ring topology, you require ADN PS
power supplies. A maximum of 15 ADN PS power supplies can be used in a confer-
ence system.
Connecting ADN PS power supplies to the ADN CU1 central unit
왘
Use a system cable to connect the
PORT II
socket
or
PORT I
socket
of the
ADN CU1 central unit to the
DATA CU/PS
input socket
of the first ADN PS
power supply (the maximum cable length allowed is 50 m).
왘
Use a system cable to connect the
DATA PS
output socket
of the first ADN PS
power supply to the
DATA CU/PS
input socket
of the second ADN PS power
supply.
왘
Repeat these steps for the remaining ADN PS power supplies.
왘
Connect the conference units to the ADN PS power supply (refer to the instruc-
tion manual of the ADN PS power supply or to the ADN system manual).
8
9
<
A
<
CU/PS
PS
DATA
CU/PS
PS
DATA
CU/PS
PS
DATA
PORT II PORT I
ADN CU1
CU/PS
PS
PORT I
1
2
PORT II
1
2
DATA
100 - 240V
50/60Hz 385W
PORT I
&
PORT II
: max. 5.25A sum
ADN PS
IN –– AUDIO –– OUT
PORT II PORT I
100-240V~
50/60Hz 240W
2x 52.8V
1.75A
8
9
<
A