background image

Instruction manual

Control Unit

ADN CU1

Summary of Contents for ADN CU1

Page 1: ...Instruction manual Control Unit ADN CU1 ...

Page 2: ......

Page 3: ... Conference Manager software 17 Connecting external audio devices to the central unit 18 Connecting a USB mass storage device for audio recordings to the central unit 18 Using the ADN CU1 central unit 18 Switching the conference system on off 18 Deactivating the lock mode of the central unit 19 Functions of the keys 19 Setting the volume of the conference units built in loudspeakers 20 Configuring...

Page 4: ...ntral unit s oper ating menu or the Conference Manager software However the full functionality of a wireless conference system can only be configured using the Conference Man ager software The software also allows you to control and monitor conferences via a graphical interface Overview of a wired conference system ADN C1 and ADN D1 wired conference units and ADN W C1 and ADN W D1 wireless confere...

Page 5: ...n length 1 8 m 1 instruction manual 1 Safety information supplement 1 DVD ROM including among other things the Conference Manager software the ADN Cable Calculator software and the instruction manual for the overall conference system as PDF ADN W AM Conference Manager software ADN CU1 max 150 ADN W D1 ADN W C1 Conferences with up to a max of 150 participants approx 30m ...

Page 6: ...max 400 ADN D1 delegate unit 502758 Allows to make contributions to the conference 1 10 optional ADN C1 chairperson unit 502759 Allows to manage the conference Number Description Cat No Function Divers SDC CBL RJ45 2 2 m 009842 Allows to interconnect components and conference units SDC CBL RJ45 3 3 m 009843 SDC CBL RJ45 5 5 m 009844 SDC CBL RJ45 10 10 m 009845 SDC CBL RJ45 20 20 m 009846 SDC CBL R...

Page 7: ...t OUT audio output PORT II socket RJ45 for connection of conference units ADN PS ADN W AM PORT I socket RJ45 for connection of conference units ADN PS ADN W AM VGA monitor output USB socket x2 Network socket RJ45 Fans Mains socket Type plate Hazard warnings IN AUDIO OUT PORT II PORT I 100 240V 50 60Hz 240W 2x 52 8V 1 75A ADN CU1 ESC 6 7 8 9 A B C F E D 1 2 3 4 5 15 1 2 3 4 5 6 7 8 9 0 A B C D E F ...

Page 8: ...ftware and or a media control unit Structural change icon Icon appears when since the last initialization a malfunction change has occurred in the cabling of the conference units Cable fault icon Icon appears when a conference unit is not correctly connected to the ADN CU1 central unit Short circuit icon Icon appears when there is a short circuit in the cabling of the conference units The display ...

Page 9: ...es max 400 conference units connected in simple strings or in ring topology per ADN PS power supply 60 70 conference units connected in simple strings 30 40 conference units connected in ring topology If cable lengths are shorter it might be that more conference units can be used ADN D1 delegate units and ADN C1 chairperson units can be combined in an arbi trary order The number of chairperson uni...

Page 10: ... number of conference units i e up to 400 you require one ADN CU1 central unit for controlling the con ference and additional ADN PS power supplies for powering the conference units The conference units are interconnected in cable strings and up to four cable strings can be connected to each ADN PS power supply PORT I PORT II ADN CU1 max 50 m approx 2 5m 52 8 V 35 V 20 1 2 3 approx 2 5m max 40 ADN...

Page 11: ...ference and additional ADN PS power supplies for powering the conference units The conference units are inter connected in rings and two rings can be connected to each ADN PS power supply When connecting the conference units to an ADN PS power supply you can mix different cable topologies simple cabling with cable strings or redun dant ring topology as long as you ensure correct cabling and comply...

Page 12: ...icient you have to power the antenna module using the NT 12 50C power supply Wireless conference system For setting up a wireless conference system up to wireless 150 conference units can be used you require one ADN CU1 central unit for controlling the conference and one ADN W AM antenna module for operating the wireless conference units range approx 30 m ADN C1 and ADN D1 wired conference units a...

Page 13: ...ware on the PC and integrate the PC together with the central unit in a network see page 17 Input and output of audio signals Via XLR sockets you can feed audio signals to the floor channel or output the floor channel For recording a conference on a USB mass storage device you can use the recording function of the ADN CU1 central unit which saves the floor channel and all channels of the conferenc...

Page 14: ...nect the mains plug EU UK or US plug of the mains cable to the mains power supply The ADN CU1 central unit is now ready for operation For information on how to mount the central unit into a 19 rack refer to the ADN system manual CAUTION Product damage due to unsuitable mains cables or power outlets An unsuitable power supply can damage the product 왘 Only use the mains cable supplied for connecting...

Page 15: ...ower supplies e g in the electrical equipment room or in the conference room 왘 Place the conference units at the corresponding seats 왘 Put out a sufficient number of SDC CBL RJ45 system cables in the required lengths If you are using wireless conference units 왘 Place the ADN CU1 central unit e g in the electrical equipment room or in the conference room If possible place the ADN W AM antenna modul...

Page 16: ... connect the OUT socket of the first conference unit to the IN socket of the second conference unit 왘 Repeat these steps for additional conference units 왘 If necessary repeat all steps for a second cable string Please note that there is a limited number of approx 15 20 conference units per cable string due to the voltage drop on the cable string see page 7 You can use optional cable holders for gu...

Page 17: ...DATA CU PS input socket of the first ADN PS power supply the maximum cable length allowed is 50 m 왘 Use a system cable to connect the DATA PS output socket of the first ADN PS power supply to the DATA CU PS input socket of the second ADN PS power supply 왘 Repeat these steps for the remaining ADN PS power supplies 왘 Connect the conference units to the ADN PS power supply refer to the instruc tion m...

Page 18: ... socket of the ADN W AM antenna module If the power supplied to the antenna module via the system cable is not suf ficient you have to power the antenna module using the NT 12 50C power supply detailed information can be found in the ADN system manual You can also connect the ADN W AM antenna module to the PORT sockets of an ADN PS power supply It does not matter if you are using a string or ring ...

Page 19: ...detailed information refer to the ADN system manual IN AUDIO OUT PORT II PORT I 100 240V 50 60Hz 240W 2x 52 8V 1 75A 0 IN AUDIO OUT PORT II PORT I 100 240V 50 60Hz 240W 2x 52 8V 1 75A A Device Requirements Screen Connection 15 pin Sub D VGA Resolution 800 x 600 pixels or higher 1024 x 768 or 1280 x 1024 pixels recommended Mouse Standard USB for Windows PCs Keyboard Standard USB for Windows PCs Sup...

Page 20: ...the ADN PS power supplies set the on off switch to position I The central unit switches on and its display panel lights up If ADN PS power supplies are connected they are also switched on Switching on a conference system comprising an antenna module for wireless operation 왘 Set the on off switch of the ADN CU1 central unit to position I The central unit switches on and its display panel lights up ...

Page 21: ... made changes to a configuration using the Conference Man ager software you have to save these changes before switching the cen tral unit off All other settings of the central unit are automatically saved 1 왘 Press the jog dial or any other key Lock appears on the display panel 왘 Turn the jog dial The Off setting is selected 왘 Press the jog dial The lock mode is deactivated Action Functions Press ...

Page 22: ...t to a high level or when several participants speak simultaneously feedback loud hissing noise can occur This can cause hearing damage 왘 Reduce the floor channel volume see below 왘 Activate the Feedback Suppression function to be able to increase the volume before feedback can occur see page 24 왘 Make sure that the Audio Gain Reduction function is activated see page 24 This function reduces the g...

Page 23: ...o Request 05 05 Select and call up the Conference Menu submenu Main Menu Conference Menu Audio Menu Wireless Menu By briefly turning the jog dial to the left or right the next or the previous menu item or setting is displayed If you turn the jog dial to the left or right and hold it in this position the menu items or settings change in quick succession fast search function Select the desired setti...

Page 24: ...ss Subnet Mask Gateway Network submenu XLR Out XLR In Floor Loudspeakers Audio Gain Reduction Feedback Suppression XLR Mix Minus Mic Loudspeaker Mute Conference Recording Audio Menu submenu XLR Out Status XLR Out Volume XLR Out Equalizer XLR Out submenu XLR In Status XLR In Sensitivity XLR In Equalizer XLR In submenu Floor Loudspeakers Volume Floor Loudspeakers Equalizer Floor Loudspeakers submenu...

Page 25: ...uest Limit Sets the maximum number of requests to speak for Request and Direct Access mode 0 10 Talk Time Status Activates deactivates the speaking time limit On Off Talk Time Limit Sets the speaking time limit 01 60 in steps of 1 minute Premonition Time Limit Sets the advance warning time warns speakers that they are approaching the end of the individual speaking time 00 120 in steps of 10 second...

Page 26: ...le audio signals during teleconferencing On Off Mic Loudspeaker Mute Deactivates the conference units built in loudspeakers for contributions coming from the conference units microphones On Off Conference Recording Calls up the Conference Recording submenu XLR Out menu XLR Out Status Activates deactivates the OUT audio output On Off XLR Out Volume Adjusts the volume of the XLR output 01 32 XLR Out...

Page 27: ...s of the audio recording and on the available memory space on the USB mass storage device Wireless Menu Country Country area settings for radio communication Europa USA Canada Mexico Channel Selection Adjusts the channel selection mode Automatic Manual Access Mode Adjusts the connection mode for wireless conference units Open Closed Switch Off Wireless Units Switches off all connected wireless con...

Page 28: ...ion Info Displays the software version Settings menu Network Calls up the Network submenu Contrast Adjusts the contrast of the display panel 1 15 Lock Activates deactivates the lock mode On Off Restore Factory Defaults Restores the factory default settings Yes No Network menu IP Address Mode Sets the IP address allocation mode Static IP Dynamic IP IP Address Sets the IP address of the central unit...

Page 29: ... ensure optimum cooling of the ADN CU1 central unit and the ADN PS power supplies 왘 Clean the air vents on the front back and bottom from time to time with a soft brush or paintbrush in order to avoid dust deposits CAUTION Liquids can damage the product Liquids entering the product can cause a short circuit in the electronics or damage the mechanics Solvents or cleansing agents can damage the surf...

Page 30: ...peration 5 C to 50 C storage 25 C to 70 C Relative humidity operation 10 to 80 storage 10 to 90 Dimensions W x H x D approx 417 x 100 x 345 mm Weight approx 6 5 kg Input resistance RIN 10 kΩ Input level max 18 dBu min 18 dBu Nominal level 7 5 dBu Output resistance ROUT 100 Ω Frequency response 20 Hz to 14 5 kHz 3 dB Output level max 11 dBu Nominal level 6 dBu THD at 1 kHz 0 02 A weighted at 7 5 dB...

Page 31: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 08 13 549158 A01 ...

Reviews: