CAUTION
-
Before dissembling the detector, power it off.
-
It is absolutely prohibited to replace battery at potential explosion or dangerous regions.
Replace the battery in a clean environment, which has no hazardous gases.
-
Replacement of components can invalidate the intrinsic safety function. Replacing the
sensor and battery should be performed by authorized sellers, agents, distributors, or safety
managers.
-
The sensors published by SENKO should be used for replacement.
Product:
Rechargeable Li-ion(polymer) power supply unit (500mAh)
-
Service task is limited to only for sensors & battery replacement. After the sensor replacement,
recommend to perform the standard calibration with CO2.
Front cover
Rear cover
PCB
Battery
Belt clip
Sensor
6. Maintenance
16