USER MANUAL – Z-SG
22
this output mode is selected)
Z-SG MODEL: not used
Bit [4]
Weight stability.
0=weight is not stable
1=weight is stable
Bit[3]
1=save the tare value in RAM memory
Bit [2]
0=gross weight is greater than tare-value
saved in memory;
1=gross weight is less than tare-value
saved in memory
Bit [1]
0=gross weight is less than load cell end
scale;
1=gross weight is greater than load cell
end scale
Bit [0]
0=net weight is less than Threshold
(reg.40054-40055) or weight measure is
not stable
1=net weight is greater than Threshold
(reg.40054-40055) and weight measure is
stable
Dip Switch
Dip Switches status refreshed at startup
Bit [15]
Switch1 of “SW1” state. 0= OFF 1 = ON
Bit [14]
Switch2 of “SW1” state. 0= OFF 1 = ON
Bit [13]
Switch3 of “SW1” state. 0= OFF 1 = ON
Bit [12]
Switch4 of “SW1” state. 0= OFF 1 = ON
unsigned
16 bit
R RAM
0
40067
66