Else use this formula:
Multiplication factor = (S203RC-D Full scale Input [mv]/ Full scale rogowski [mV])*(Full
scale rogowski[A]/1000)
for example:
Input full scale of +-100mV and Rogowski coil of 100mV/500A use 0,500
Input full scale of +-100mV and Rogowski coil of 100mV/2000A use 2,000
Input full scale of +-200mV and Rogowski coil of 200mV/2000A use 2,000
Etc…
F6) CURRENT PHASE C
Set a multiplication factor for IRMS C
Default: 1,000
ONLY FOR S203RC-D model:
For Rogowski coil of 100mV/1000A use multiplication factor of 1,000 (factory default)
Else use this formula:
Multiplication factor = (S203RC-D Full scale Input [mv]/ Full scale rogowski [mV])*(Full
scale rogowski[A]/1000)
for example:
Input full scale of +-100mV and Rogowski coil of 100mV/500A use 0,500
Input full scale of +-100mV and Rogowski coil of 100mV/2000A use 2,000
Input full scale of +-200mV and Rogowski coil of 200mV/2000A use 2,000
Etc…