USER MANUAL – S203TA-D / S203RC-D
37
Default: normally open
6.3.1.
F) User Taratures
PARAMETER
VALUES
F1) VOLT PHASE A
Set a multiplication factor for VRMS A
Default: 1,000
F2) VOLT PHASE B
Set a multiplication factor for VRMS B
Default: 1,000
F3) VOLT PHASE C
Set a multiplication factor for VRMS C
Default: 1,000
F4) CURRENT PHASE A
Set a multiplication factor for IRMS A
Default: 1,000
ONLY FOR S203RC-D model:
For Rogowski coil of 100mV/1000A use multiplication factor of 1,000 (factory default)
Else use this formula:
Multiplication factor = (S203RC-D Full scale Input [mv]/ Full scale rogowski [mV])*(Full
scale rogowski[A]/1000)
for example:
Input full scale of +-100mV and Rogowski coil of 100mV/500A use 0,500
Input full scale of +-100mV and Rogowski coil of 100mV/2000A use 2,000
Input full scale of +-200mV and Rogowski coil of 200mV/2000A use 2,000
Etc…
F5) CURRENT PHASE B
Set a multiplication factor for IRMS B
Default: 1,000
ONLY FOR S203RC-D model:
For Rogowski coil of 100mV/1000A use multiplication factor of 1,000 (factory default)