Senco Fusion F-LXP Operating Instructions Manual Download Page 3

3

SYMBOLS

The following signal words and meanings are intended to explain the levels of risk associated with this product.

SYMBOL

SIGNAL

MEANING

DANGER:

Indicates a hazardous situation, which, if not avoided, will result in death or 
serious injury.

WARNING:

Indicates a hazardous situation, which, if not avoided, could result in death or 
serious injury.

CAUTION:

Indicates a hazardous situation, which, if not avoided, may result in minor or 
moderate injury.

NOTICE:

(Without Safety Alert Symbol) indicates information considered important, but 
not related to a potential injury (e.g. messages relating to property damage).

Some of the following symbols may be used on this product. Please study them and learn their meaning.  

Proper interpretation of these symbols will allow you to operate the product in a better, safer manner.

SYMBOL

NAME

DESIGNATION/EXPLANATION

Safety Alert

Indicates a potential personal injury hazard.

Read Operator’s 

Manual

To reduce the risk of injury, user must read and understand operator’s manu-
al before using this product.

Eye Protection

Always wear eye protection with side shields marked to comply with ANSI 
Z87.1.

Do not rest your finger on the trigger when picking up the tool, moving 
between operating areas and positions or walking, as resting finger on trigger 
can lead to inadvertent operation. For tools with selective actuation, always 
check the tool before use to ascertain the correct mode is selected. 
This tool has either selective actuation for contact actuation or continuous 
contact actuation by actuation mode selectors or is a contact actuation or con-
tinuous actuation contact tool and has been marked with the symbol above. 
If using this tool in selective actuation mode, always ensure it is in the correct 
actuation setting.
Be careful when changing from one driving location to another.

R

Do Not Oil

Routine lubrication is not necessary.

Wet Conditions 

Alert

Do not expose to rain or use in damp locations.

Recycle

This product uses Lithium-ion batteries. Local, state, or federal laws may pro-
hibit disposal of batteries in ordinary trash. Consult your local waste authority 
for information regarding available recycling and or disposal options.

V

Volts

Voltage

Direct Current

Type or characteristic of current

Summary of Contents for Fusion F-LXP

Page 1: ...erating Instructions KYOCERA SENCO Industrial Tools Inc 8450 Broadwell Road Cincinnati OH 45244 1 800 543 4596 www senco com 2021 by KYOCERA SENCO Industrial Tools Inc NFD810YENG Issued April 30 2021...

Page 2: ...afety Warnings 6 Additional Tool Safety Warnings 7 Safety Warnings for Charger and Battery 9 Functional Description 11 Tool Operation 12 Mode Selection 12 Warning Light 14 Time Out Lockout 15 Depth of...

Page 3: ...g this product Eye Protection Always wear eye protection with side shields marked to comply with ANSI Z87 1 Do not rest your finger on the trigger when picking up the tool moving between operating are...

Page 4: ...carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock 8 When operating a power tool out...

Page 5: ...re caused by poorly maintained power tools 23 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control 24 Use the...

Page 6: ...ol While removing a jammed fastener the stapler may be accidentally activated if it is energized 5 Use caution while removing a jammed fastener The mechanism may be under compression and the fastener...

Page 7: ...nt and trigger Do not use tool if workpiece contact element or trigger sticks or binds Always remove finger from trigger when not driving fasteners Never carry the tool with finger on or under trigger...

Page 8: ...rea MUST wear safety glasses with side shields Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing Choice of triggering method is important See page 13 14 for triggeri...

Page 9: ...ngth of Cord Feet AWG Size of Cord Longueur du cordon en m Taille AWG du cordon Largo del cable m pies Calibre AWG del cable 25 150 100 50 7 5 45 30 15 16 14 16 16 16 14 16 16 16 14 16 16 7 5 45 30 15...

Page 10: ...the battery cartridge even if it is severely damaged or is completely worn out The battery cartridge can explode in a fire Never attempt to connect two 2 chargers together This appliance is not intend...

Page 11: ...elt Hook ON OFF Mode Selector Magazine Latch Battery Depth of Drive Adjustment Workpiece Contact For authorized service center use only Removeable Cap Pressure Release Port Trigger Magazine Release Fu...

Page 12: ...e new battery before using see To Charge Battery on page 17 Indicator LED ON The tool should be switched off when not in use Hold down either side of the selector switch for 1 second to turn the tool...

Page 13: ...switch for 0 5 seconds This will be indicated by the flashing green LED on the selector switch 2 Pull trigger 3 Depress workpiece contact element against work surface and drive a fastener This mode of...

Page 14: ...echarge the battery or replace with a freshly charged battery to continue If the tool has detected this condition first it is usually due to sustained extreme use Replace the battery with a fully char...

Page 15: ...the nosepiece The light will indicate that the electronic controls are energized while providing illumination of the workpiece in low light situations The light will flash three times when the select...

Page 16: ...ack on via mode selector switch Tool will attempt to recover Should a severe fastener jam occur Turn the tool off by depressing the selector switch towards either mode symbol for approximately 1 secon...

Page 17: ...uired to be fully charged A maximum charge time of 1 hour is required to recharge a completely dis charged battery pack Maintenance charge is indicated when the red light turns off while the green lig...

Page 18: ...l 1 800 8BATTERY Maintenance Read section titled Safety Warnings before maintaining tool 1 With battery removed make daily inspection to ensure free movement of workpiece contact and trigger Do not us...

Page 19: ...5 8 16 L11 3 4 19 L12 7 8 22 L13 1 25 L14 1 1 8 28 5 L15 1 1 4 32 L17 1 1 2 38 Technical Specifications F LXP TECHNICAL SPECIFICATIONS Voltage 18 volts Li ion Weight with Battery 6 6 lbs 3 0 kg Heigh...

Page 20: ...mechanism initiates an automatic recovery the tool may make a series of clicks as it repositions the driver This is normal Tool will not start or runs slowly Battery is discharged or has dead cell Rep...

Page 21: ...amily of products SENCO brings 50 years of commitment to our customers and to power fastening systems We are dedicated to making sure your tools are performing at their best and we understand that ens...

Page 22: ...roducts used in production industrial applications as defined by SENCO are excluded from this warranty 4 Labour charges or loss or damage resulting from improper operation maintenance or repairs are n...

Page 23: ......

Page 24: ......

Reviews: