Senco Fusion F-LXP Operating Instructions Manual Download Page 14

TOOL OPERATION

14

This tool is equipped with an indicator light at the ON/OFF/MODE switch. See page 14 for detailed 
instructions.

Note:

When the tool is in the sequential mode, a fastener cannot be driven by pulling the trigger before 
activating the work piece contact element.
If the workpiece contact is activated for more than 10 seconds, the workpiece contact must be 
released to start over.
When the tool is in contact actuation mode, if the operator holds the trigger on for more than 3 
seconds, the light will go out and the trigger must be released to start over. 

This tool is equipped with a multi-purpose light in the 
mode switch. The mode sensor light will indicate that the 
electronic controls are energized, which operating mode 
has been selected, if a jam was detected and when the 
battery requires a full recharge.

Solid or Flashing Green Light

Indicates the tool is energized and ready to drive. 

If light does not turn on, look to be sure that the trigger or work contact element are free to move and not in the activated 
position. 

Solid Red Light

Indicates the tool has detected an error.

Low battery. The battery will usually detect the condition first and turn the tool off. Recharge the battery or replace with 
a freshly charged battery to continue. If the tool has detected this condition first, it is usually due to sustained extreme 
use. Replace the battery with a fully charged battery.
The tool detected a timing issue. This can be caused by low charge pressure,  an application requiring drive energy 
above the tools capacity, a loose battery connection or broken components. Re-insert the battery or replace the battery 
with a freshly charged battery. If this does not remedy the issue, refer to the troubleshooting guide or contact an autho-
rized service center.

Flashing Red Light

Indicates a fastener jam.

The tool detects a jam which is usually due to a deformed staple wedged in the driver path.
Remove the battery from tool, re-insert battery and turn on tool.  If tool does not return to normal operation, go to next step.
REMOVE the BATTERY
Unload all remaining fasteners in magazine. Make sure that any loose fastener from strip is also removed.
Access the jammed fastener via the open magazine.
Carefully remove the jammed fastener.
Close the magazine.
Attach charged battery to tool.
Load staples into magazine.
Resume normal operation.

If the wedged fastener can’t be removed, return to an authorized service center where the damaged 
fastener can be removed. Remember that the Fusion tool contains pressurized air at all times even 
when the battery is removed.

Summary of Contents for Fusion F-LXP

Page 1: ...erating Instructions KYOCERA SENCO Industrial Tools Inc 8450 Broadwell Road Cincinnati OH 45244 1 800 543 4596 www senco com 2021 by KYOCERA SENCO Industrial Tools Inc NFD810YENG Issued April 30 2021...

Page 2: ...afety Warnings 6 Additional Tool Safety Warnings 7 Safety Warnings for Charger and Battery 9 Functional Description 11 Tool Operation 12 Mode Selection 12 Warning Light 14 Time Out Lockout 15 Depth of...

Page 3: ...g this product Eye Protection Always wear eye protection with side shields marked to comply with ANSI Z87 1 Do not rest your finger on the trigger when picking up the tool moving between operating are...

Page 4: ...carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock 8 When operating a power tool out...

Page 5: ...re caused by poorly maintained power tools 23 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control 24 Use the...

Page 6: ...ol While removing a jammed fastener the stapler may be accidentally activated if it is energized 5 Use caution while removing a jammed fastener The mechanism may be under compression and the fastener...

Page 7: ...nt and trigger Do not use tool if workpiece contact element or trigger sticks or binds Always remove finger from trigger when not driving fasteners Never carry the tool with finger on or under trigger...

Page 8: ...rea MUST wear safety glasses with side shields Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing Choice of triggering method is important See page 13 14 for triggeri...

Page 9: ...ngth of Cord Feet AWG Size of Cord Longueur du cordon en m Taille AWG du cordon Largo del cable m pies Calibre AWG del cable 25 150 100 50 7 5 45 30 15 16 14 16 16 16 14 16 16 16 14 16 16 7 5 45 30 15...

Page 10: ...the battery cartridge even if it is severely damaged or is completely worn out The battery cartridge can explode in a fire Never attempt to connect two 2 chargers together This appliance is not intend...

Page 11: ...elt Hook ON OFF Mode Selector Magazine Latch Battery Depth of Drive Adjustment Workpiece Contact For authorized service center use only Removeable Cap Pressure Release Port Trigger Magazine Release Fu...

Page 12: ...e new battery before using see To Charge Battery on page 17 Indicator LED ON The tool should be switched off when not in use Hold down either side of the selector switch for 1 second to turn the tool...

Page 13: ...switch for 0 5 seconds This will be indicated by the flashing green LED on the selector switch 2 Pull trigger 3 Depress workpiece contact element against work surface and drive a fastener This mode of...

Page 14: ...echarge the battery or replace with a freshly charged battery to continue If the tool has detected this condition first it is usually due to sustained extreme use Replace the battery with a fully char...

Page 15: ...the nosepiece The light will indicate that the electronic controls are energized while providing illumination of the workpiece in low light situations The light will flash three times when the select...

Page 16: ...ack on via mode selector switch Tool will attempt to recover Should a severe fastener jam occur Turn the tool off by depressing the selector switch towards either mode symbol for approximately 1 secon...

Page 17: ...uired to be fully charged A maximum charge time of 1 hour is required to recharge a completely dis charged battery pack Maintenance charge is indicated when the red light turns off while the green lig...

Page 18: ...l 1 800 8BATTERY Maintenance Read section titled Safety Warnings before maintaining tool 1 With battery removed make daily inspection to ensure free movement of workpiece contact and trigger Do not us...

Page 19: ...5 8 16 L11 3 4 19 L12 7 8 22 L13 1 25 L14 1 1 8 28 5 L15 1 1 4 32 L17 1 1 2 38 Technical Specifications F LXP TECHNICAL SPECIFICATIONS Voltage 18 volts Li ion Weight with Battery 6 6 lbs 3 0 kg Heigh...

Page 20: ...mechanism initiates an automatic recovery the tool may make a series of clicks as it repositions the driver This is normal Tool will not start or runs slowly Battery is discharged or has dead cell Rep...

Page 21: ...amily of products SENCO brings 50 years of commitment to our customers and to power fastening systems We are dedicated to making sure your tools are performing at their best and we understand that ens...

Page 22: ...roducts used in production industrial applications as defined by SENCO are excluded from this warranty 4 Labour charges or loss or damage resulting from improper operation maintenance or repairs are n...

Page 23: ......

Page 24: ......

Reviews: