Senco Fusion F-LXP Operating Instructions Manual Download Page 15

15

TOOL OPERATION

6

12

3

9

1

2

This tool is equipped with an electronic “Time-Out” feature. This tool will temporarily 
be disabled under any of the following conditions:

1.  Workpiece contact element is depressed against the work piece, but the trigger  
  is not pressed within approximately 10 seconds.
2.  Trigger is pressed, but work piece contact element is not depressed within  
  approximately 3 seconds. (Contact-Actuation mode only.)

• Simply release trigger and release workpiece contact element to resume 
normal operation.

The tool is equipped with a last fastener lockout. The tool will not fire the last 4-7 
fasteners. This feature prevents unnecessary wear on the tool and prevents the driver 
tip from marring the workpiece. When the tool locks out, load an additional strip and 
continue. It is not necessary to remove the remaining fasteners from the magazine.

This tool is equiped with a dual-purpose light on the nosepiece. The light will indicate 
that the electronic controls are energized while providing illumination of the workpiece 
in low light situations. The light will flash three times when the selector switch is 
switched to either sequential or contact actuation. This lets the user know that the tool 
is ready to fire a fastener. The light will remain on for ten seconds when the trigger is 
pulled or the work contact element is depressed.

This tool is equipped with depth-of-drive dial. Turning the dial to the right will counter-
sink the fastener, turning the dial to the left will leave the fastener up or raised. Drive a 
fastener into a scrap piece of wood to test depth.
Turning the dial in the direction shown in the image will result in the fastener driving 
deeper into the wood.

This tool is equipped with an adjustable 6 position belt hook for 
right and left handed operators. The hook will safely support the 
tool when hanging from joists and rafters.
Rotate the knurled knob to adjust opening or to switch from 
right to left side. Move black plastic cap to alternate side to 
complete assembly.

Summary of Contents for Fusion F-LXP

Page 1: ...erating Instructions KYOCERA SENCO Industrial Tools Inc 8450 Broadwell Road Cincinnati OH 45244 1 800 543 4596 www senco com 2021 by KYOCERA SENCO Industrial Tools Inc NFD810YENG Issued April 30 2021...

Page 2: ...afety Warnings 6 Additional Tool Safety Warnings 7 Safety Warnings for Charger and Battery 9 Functional Description 11 Tool Operation 12 Mode Selection 12 Warning Light 14 Time Out Lockout 15 Depth of...

Page 3: ...g this product Eye Protection Always wear eye protection with side shields marked to comply with ANSI Z87 1 Do not rest your finger on the trigger when picking up the tool moving between operating are...

Page 4: ...carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock 8 When operating a power tool out...

Page 5: ...re caused by poorly maintained power tools 23 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control 24 Use the...

Page 6: ...ol While removing a jammed fastener the stapler may be accidentally activated if it is energized 5 Use caution while removing a jammed fastener The mechanism may be under compression and the fastener...

Page 7: ...nt and trigger Do not use tool if workpiece contact element or trigger sticks or binds Always remove finger from trigger when not driving fasteners Never carry the tool with finger on or under trigger...

Page 8: ...rea MUST wear safety glasses with side shields Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing Choice of triggering method is important See page 13 14 for triggeri...

Page 9: ...ngth of Cord Feet AWG Size of Cord Longueur du cordon en m Taille AWG du cordon Largo del cable m pies Calibre AWG del cable 25 150 100 50 7 5 45 30 15 16 14 16 16 16 14 16 16 16 14 16 16 7 5 45 30 15...

Page 10: ...the battery cartridge even if it is severely damaged or is completely worn out The battery cartridge can explode in a fire Never attempt to connect two 2 chargers together This appliance is not intend...

Page 11: ...elt Hook ON OFF Mode Selector Magazine Latch Battery Depth of Drive Adjustment Workpiece Contact For authorized service center use only Removeable Cap Pressure Release Port Trigger Magazine Release Fu...

Page 12: ...e new battery before using see To Charge Battery on page 17 Indicator LED ON The tool should be switched off when not in use Hold down either side of the selector switch for 1 second to turn the tool...

Page 13: ...switch for 0 5 seconds This will be indicated by the flashing green LED on the selector switch 2 Pull trigger 3 Depress workpiece contact element against work surface and drive a fastener This mode of...

Page 14: ...echarge the battery or replace with a freshly charged battery to continue If the tool has detected this condition first it is usually due to sustained extreme use Replace the battery with a fully char...

Page 15: ...the nosepiece The light will indicate that the electronic controls are energized while providing illumination of the workpiece in low light situations The light will flash three times when the select...

Page 16: ...ack on via mode selector switch Tool will attempt to recover Should a severe fastener jam occur Turn the tool off by depressing the selector switch towards either mode symbol for approximately 1 secon...

Page 17: ...uired to be fully charged A maximum charge time of 1 hour is required to recharge a completely dis charged battery pack Maintenance charge is indicated when the red light turns off while the green lig...

Page 18: ...l 1 800 8BATTERY Maintenance Read section titled Safety Warnings before maintaining tool 1 With battery removed make daily inspection to ensure free movement of workpiece contact and trigger Do not us...

Page 19: ...5 8 16 L11 3 4 19 L12 7 8 22 L13 1 25 L14 1 1 8 28 5 L15 1 1 4 32 L17 1 1 2 38 Technical Specifications F LXP TECHNICAL SPECIFICATIONS Voltage 18 volts Li ion Weight with Battery 6 6 lbs 3 0 kg Heigh...

Page 20: ...mechanism initiates an automatic recovery the tool may make a series of clicks as it repositions the driver This is normal Tool will not start or runs slowly Battery is discharged or has dead cell Rep...

Page 21: ...amily of products SENCO brings 50 years of commitment to our customers and to power fastening systems We are dedicated to making sure your tools are performing at their best and we understand that ens...

Page 22: ...roducts used in production industrial applications as defined by SENCO are excluded from this warranty 4 Labour charges or loss or damage resulting from improper operation maintenance or repairs are n...

Page 23: ......

Page 24: ......

Reviews: