![Sena Rhio10 User Manual Download Page 71](http://html1.mh-extra.com/html/sena/rhio10/rhio10_user-manual_1237630071.webp)
71
- if option='- ip', all parameters except IP
settings are set with factory default values.
“ERROR” +
<CR>
+
<LF>
save + <CR>
Save changes
If success,
“OK”+ <CR> + <LF>
If error
“ERROR” +
<CR>
+
<LF>
exit + <CR>
Exit without rebooting the device (changes
are not applied)
If success,
“OK”+ <CR> + <LF>
If error
“ERROR” +
<CR>
+
<LF>
r eboot + <CR>
Exit and reboot the device
None
B.2.1 'set' Command
With ‘set’command, users can configure parameter values of the RHIO10 for each environment.
Basic ‘set’command usage is as follows:
set group par1 [par2 ...] + <CR>
where,
group = 'ip','host','serial' or 'admin'
par1 par2 ... = configuration parameters. Use * to keep a parameter's value
The ‘group’is the category where the parameters should be entered. For example, if users want
to set parameters related to the IP configuration, use set command as shown in the Figure B -5.
> set ip static 192.168.1.100 255.255.255.0 192.168.1.1
OK
>
Figure B-5 IP configuration example screen
In the above example, the first parameter ‘ip’ indicates that the following parameters are IP
configuration parameters. The second parameter ‘static’indicates that the RHIO10 will use static
IP address of the third parameter ‘192.168.1.100’. The fifth parameter indicates the subnet mask
and the next indicates the default gateway IP address.