![Sena Rhio10 User Manual Download Page 57](http://html1.mh-extra.com/html/sena/rhio10/rhio10_user-manual_1237630057.webp)
57
“00000”
“50000”
OFF after 5,000 sec delay
“00001”
“00001”
Repeat 100 ms ON and 100 ms OFF.
“00020”
“00020”
Repeat 2 sec ON and 2 sec OFF.
“50000”
“50000”
Repeat 5,000 sec ON and 5,000 sec
OFF.
“00010”
“00030”
Repeat 1 sec ON and 3 sec OFF.
“00300”
“00150”
Repeat 30 sec ON and 15 sec OFF.
5.3.5.2 Response for Set Output Port command
Response
Data
Remark
Byte
Size
2
1
2
1
N
“06”
( 0x30,
0x36 )
Return
setting.
Setting
Flag
Port
No.
“01”
-
“10”
0x30: Clear run condition
0x31: Set run condition
0x32: Clear Delay/Pulse
0x33: Set Delay/Pulse
0x39: Clear all settings
Setting
Data
Return the setting
of an output port.
-
Setting Flag
0x30: Set OK
0x39: Set NG
0x31: Not in Setting mode (when in Run mode)
0x32: Unspecified (If the user attempts to clear in unspecified state, it will return 0x32.)
(When it is in unspecified state, the setting data is 0x30 in 1 byte.)
-
When setting is cleared, the setting data is 0x30 in 1 byte.
5.3.5.3 Check Output Port Setting Command
Command
Data
Remark
Byte Size
2
2
1
“07”
( 0x30, 0x37 )
Check setting.
Port No.
“01” - “10”
0x31:
Check
the
run
condition setting.
0x33:
Check
the
Delay/Pulse setting
Check the attribute
of each output port.