![Sena Rhio10 User Manual Download Page 59](http://html1.mh-extra.com/html/sena/rhio10/rhio10_user-manual_1237630059.webp)
59
-
Setting Flag
0x30: Set OK
0x31: Not in Setting mode (in Run mode)
0x39: Set NG
5.3.6.3 Check ADC Input Port Setting Command
Command
Data
Remark
Byte Size
2
1
“10”
( 0x31, 0x30 )
Check the ADC
setting
0x30: Fixed to a dummy
value
Check the
threshold level
value of an input
ADC port.
5.3.6.4 Response for Check ADC Input Port Setting command
-
Same as "
5.3.6.2 Response for Set Port command
".
-
The setting field is always OK (0x30).
-
The factory default value in Level Input mode is set to "0000".
5.3.7 Port Enable Setting
5.3.7.1 Set Port Enable command
Command
Data
Remark
Byte Size
2
34
“11”
( 0x31, 0x31 )
Set to Enable.
Port Enable/Disable setting data
Set all ports to
Enable/Disable.
-
Data
Field
Data Order
Port
Data Content
1
A1
2
A2
3
A3
ADC Port
4
A4
0x31: Level Input mode
0x32: Switch Input mode