![Sena Rhio10 User Manual Download Page 37](http://html1.mh-extra.com/html/sena/rhio10/rhio10_user-manual_1237630037.webp)
37
4.3.3 Delay & Pulse Operation
If the [
Use Delay/Pulse
] check box is selected, the output port executes Delay and Pulse
operation. The setting value for Delay and Pulse can be entered in 100 ms.
-
When Delay ON is selected, you can send the
Output Port ON
command to set an
output port to ON after a specified delay time has passed.
-
When Delay OFF is selected, you can send the
Output Port OFF
command to set an
output port to OFF after a specified delay time has passed.
-
When Pulse is selected, the port continues to toggle between ON and OFF according
to the specified ON/OFF time.
4.3.4 Setting Power-out Post Recovery
Power -out Post Recovery can be set for an output port using the [Setting power stoppage
rehabitation] pane in the Setting window.
-
If it is enabled, Rhio10 retains its output port states prior to power-out when power goes
out and back on
-
If Power-out Post Recovery is enabled for an output port that has been set with an
operation condition, the port becomes ON when power is restored if the operation
condition is satisfied.
-
If it is disabled, the output port state becomes OFF when power goes out and back on.
4.4 ADC Input Port Setting
Rhio10 has 4 ADC input ports. You can set an ADC input port with Rhio Manager or by issuing
commands via an I/O port protocol (refer to "
Ch. 5 I/O Port Related Protocols
”).
When using Rhio Manager, place the mouse cursor over the ADC Port LED on the [I/O Port
Control] screen and right-click it to display the Setting ADC port windows as shown below: