ENGLISH
808-000-000
Sematic Drive System
©
13
© SEMATIC
z
All rights reserved
Changes can be made without notice
see
www.sematic.com
for latest release
w w w. s e m a t i c . c o m
Signal
Connector
Pins
Contact Type &
Normal State
Notes
INCOMING SIGNALS FROM THE DOOR CONTROLLER
Opening control Ka
(coming from the Main
Lift Controller)
Connector
pins 5 - 15
These connections require
dry (voltage free) contacts
(contact open when inac-
tive)
When the Door Controller is
installed on a Front & Rear
entrance car, it is important
that the opening and closing
controls have no common con-
tacts between the two doors.
Shielded, Grounded Wire
Highly Recommended
Closing control Kc
(coming from the Main
Lift Controller)
Connector
pins 3 - 15
These connections require
dry (voltage free) con-
tacts. (contact open when
inactive)
Forced closing
control at
low speed Kb
Connector
pins 15 - 22
These connections require
dry (voltage free) contacts
(contact open when inac-
tive)
The main lift controller may
signal the forced closing when
the photocell (or similar device)
shall be made inoperative due
to a failure, or after several
door closing failures.
Re-Opening control Kn
Connector
pins 15 - 23
These connections require
dry (voltage free) con-
tacts. (both logics availa-
ble)
See sections 4.1.1 & 4.1.2. for
the connection to the door
controller
Fire-Fighting Contact
Kff
Connector
pins 15 - 39
These connections require
dry (voltage free) con-
tacts. (contact open when
inactive)
See section 6.9
Contact K2TB
Connector
pins 15 - 41
These connections require
dry (voltage free) con-
tacts.
(contact open when inac-
tive)
This signal allows the door
controller to recognize diffe-
rent door opening widths in
the same lift installation.
Given this signal, the opening
and closing operations are car-
ried out referring to an alter-
native TB (door width recorded
by an additional self-learning
cycle).
Encoder
Signals
Connector
RJ45 (A)
Factory prewired
connector
Handset (Optional)
RJ45 connec-
tor (B)
Auxiliary Contact Kaux
Connector
pins 15 - 42
These connections require
dry (voltage free) con-
tacts. (contact open when
inactive)
Not yet implemented
Contact KEOD
Connector
pins 15 - 40
These connections require
dry (voltage free) con-
tacts. (contact open when
inactive)
This connection is to signal the
use of the Sematic E.O.D.
Emergency Opening Device to
the Door controller