DT-E 1.3: SUN PROTECTION SCREEN – VENETIAN BLINDS C80P and C80L
Issue 3 / April 2017 / EN
page 53 / 62
In rooms and spaces where there are increased threat conditions, automatic devices for switching off power supply to the
damaged product should be used, e.g. residual current devices. They are recommended to be used in bathrooms, kitchens,
garages and cellars. Are obligatory to be used at swimming and shower pools, saunas, construction sites, while supplying
appliances in open spaces, on agricultural and horticultural farms, on campsites and in camper vans, as well as in rooms
where there is fire hazard.
4.6.2.
START-UP AND ADJUSTMENT
extreme position (up and down movement of the slats) are protected by limit switches that need to be adjusted
during the installation,
adjustment of limit switches must be done in accordance with motor’s maintenance manual,
prior to the first start of the product electrical measurements should be performed,
do not start the engine without checking the correctness of system installation.
When the product starts working attention should be paid to:
correct opening and closing of the product
correct activation of limit switches
Incorrect connection of the motor can lead to product damage or create a hazardous situation.
The engine has a thermal switch, which turns off the drive after about 4 minutes of continuous work to
protect against overheating. After turning off by the thermal protection appropriate time should pass
before turning on again, depending on the type of engine and atmospheric conditions (about 16
minutes).
4.6.3.
MANUAL DRIVE
Opening, closing and setting slats tilt angle is performed with the use of a crank.
Do not use excessive force when the blind reaches end position.
Crank should be secured with crank bracket.
1.
Cover panel main
bracket
2.
Head rail
3.
Wall-grommet
4.
Gear
5.
Max 500mm