5.5) Connections for central adapter and remote control connector (fig. 5 )
Note:
- To connect the trigger on the torch, use the central adapter only;
- The sole purpose of the military connector is to connect the button on the remote control, where applicable
(e.g.: RC 12);
- if there is a potentiometer, it should have a value in the range [2.5 ~ 10] k .
8
Wiring and connection diagrams
FRONT VIEWS
CENTRAL TORCH ADAPTER
REMOTE CONTROL
3 - 5 = Torch trigger
A = EXT +V
B = EXT GND
C = EXT RIF
D = -
(not connected)
E = -
(not connected)
F = -
(not connected)
G = EXT Torch trigger