Section 7: Valve Maintenance
MAX Valve Repair and Replacement
2016 Bambi MAX Service Manual
–
Models 4453-7590
(Version D)
37
We Engineer Solutions
5.
Connect the power control cable to a 24-28 volt
DC power source, open the valve about a 1/3 of
the way and cut the power. The cable anchor
should be close to the position shown in this
picture. Now, feed the cable through the cable
anchor, pull it snug but do not tighten.
6.
Install a 3/8" spacer plate between the
sheave bar and lift bar. Place a heavy
weight on the lift bar to hold it down.
7.
Turn on the power. The valve will close.
Pull the cable tight and secure with cable
anchor screws.
Weight
3/8" spacer