Section 7: Valve Maintenance
MAX Valve Repair and Replacement
2016 Bambi MAX Service Manual
–
Models 4453-7590
(Version D)
34
We Engineer Solutions
6.
Now, start all bolts into the tube, turning
them in about 1/8". This allows you to
locate the holes in the tube easier by lifting
the ring and seal to see the holes.
7.
Tighten all bolts equally as they are going into plastic. Do not over tighten as you would in metal.
8.
String the control line and, before unrolling the
coil of cable, pass it through the center of the
IDS hub. Once all the cable is outside the
bucket with no slack, push it 6" back into the
bucket. Now, using tie-wraps, attach the cable
to the deployment cable eye on the hub. Use at
least two tie-wraps.
9.
Reattach the control cable to the IDS deployment cable using tie-wraps or tape spaced about 36"
apart. At the head, the final attachment will be at the IDS cable shackle.