Section 6: Troubleshooting and Maintenance
Troubleshooting
2016 Bambi MAX Service Manual
–
Models 4453-7590
(Version D)
23
We Engineer Solutions
Section 6: Troubleshooting and Maintenance
Troubleshooting
Valve Troubleshooting
Problem
Status Lamp
Possible Cause
Solution
Circuit breaker tripped
Reset circuit breaker.
No Power
Off (W hite)
Aircraft / longline wiring
Check aircraft / longline
wiring.
Aircraft / longline wiring
Check aircraft / longline
wiring.
Mechanical jamb
Clear jamb / check linkage
Valve adjusted too high Adjust valve down.
Circuit Breaker
Trips
Off (W hite)
Valve adjusted too low
Adjust valve up.
Flashing
Green
Motor protector
activated
Power cycle to reset.
Adjust valve up.
No open signal
Check aircraft / longline
wiring.
Yellow
Controller failure
Contact service center.
Green
Damaged drive cable
Replace drive cable.
Valve Closed
Won't Open
Red
Controller / sensor
failure
Contact service center.
Flashing
Green
Motor protector
activated
Power cycle to reset.
Adjust valve down.
Green
Controller failure
Contact service center.
Yellow
Damaged drive cable
Replace drive cable.
Valve Open
Won't Close
Red
Controller / sensor
failure
Contact service center.
Damaged seals
Replace seals.
Valve Leaks
Yellow
Valve adjusted too high Adjust valve down.