Section 7: Maintenance
Maintenance and Servicing
Sacksafoam II Model 8044 Operations Manual
(Version C)
15
Section 7: Maintenance
Maintenance and Servicing
The Sacksafoam II unit requires no maintenance other than cleaning. The unit should be flushed out with
clean water daily, after use, and prior to storage.
Flushing Procedure
1.
Insert one dip tube into a container of clean water.
2.
Place the breakaway hose into a bucket and operate the Sacksafoam controller until the water runs
clean.
3.
Repeat step #2 for the other dip tube. Drain any remaining water from the piping and pump by
alternately holding the dip tubes upside down and operating the Sacksafoam controller.
4.
Foam or water in the Sacksafoam case can be drained by removing the drain cap and tipping the
unit. Wipe out the case with a damp cloth.
5.
Remove the drip tube to drain any residual foam.
Important Note
Proper cleaning of the equipment prior to storage will increase the life span of the unit.
Caution
Residual foam will form a waxy substance that can prevent proper operation of the Sacksafoam.