Section 5: Controller Box
Controller Box Functions
Sacksafoam II Model 8044 Operations Manual
(Version C)
11
Controller Box Functions
Item Function
On/off switch
Toggle up to turn ON.
Toggle down to turn off and reset.
Dispense
switch
Press/push button to begin dispensing foam.
Dispense
time switch
Push buttons to set run time of foam injection pump.
Current
drops
counter
Both counters increment every time dispense switch is pressed up (on). Current
drops counter should be reset when Sacksafoam is refilled. Zero counter by
pressing reset button.
Total drops
counter
Both counters increment every time dispense switch is pressed up (on). Total
drops counter can be used to count the total number of drops per day or shift.
Zero counter by pressing reset button.
Red power
light
Red light is on when power is on.
Orange
dispense
light
Orange light is on when unit is dispensing foam.
Green mix
ready light
Green light is on when unit is ready for next dispense cycle or mixer (if installed)
is running. The green light (and mixer; if installed) will go off when the Bambi
bucket is dumped if green wire is hooked up to Bambi dump circuit.
Important Note
If the power supply polarity is reversed, the controller box will not operate. However, the Sack-
safoam dispense pump will operate at a greatly reduced flow rate. If reverse polarity occurs, cor-
rect it immediately.