Section 7: Maintenance
Maintenance and Servicing
Sacksafoam II Model 8044 Operations Manual
(Version C)
16
Servicing
The gray plastic mounting panel carrying the pump, valves and electrical control box can be removed for
servicing.
To remove the mounting panel:
1.
Remove the three bolts holding the
pail. Separate the interior frame.
2.
Remove the three bolts holding the
mounting panel.
3.
Lift the assembly straight up with the
wires attached. Lay the panel on top of
the container.
The pump impeller can be serviced without removing the pump from the mounting panel. Remove the four
brass screws on the bottom of the pump to access the impeller. A spare impeller and seal are supplied with
each Sacksafoam II unit.
If a solenoid valve does not operate properly, remove the blue coil by pulling off the securing clips (do not
lose the wave washer installed under the coil).
Undo the four bolts and gently remove the top of the valve from the diaphragm. Clean the inside of the valve
and the diaphragm using mild soap and water (do not lose the small spring that fits inside the metal stem
attached to the diaphragm).
Test the unit after any servicing.
Bambi panel shown in photo.